Literature DB >> 20619439

River phosphorus cycling: separating biotic and abiotic uptake during short-term changes in sewage effluent loading.

M I Stutter1, B O L Demars, S J Langan.   

Abstract

Medium to small scale point sources continue to threaten river ecosystems through P loadings. The capacity and timescales of within-river processing and P retention are a major factor in how rivers respond to, and protect downstream ecosystems from, elevated concentrations of soluble reactive P (SRP). In this study, the bio-geochemical response of a small river (approximately 40 km(2) catchment area) was determined before, during and after exposure to a fourteen day pulse of treated sewage effluent using an upstream reach as a control. A wide array of approaches (batch and column simulations to in-situ whole stream metabolism) allowed independent comparison and quantification, of the relative contribution of abiotic and biotic processes in-river P cycling. This enabled, for the first time, separating the relative contributions of algae, bacteria and abiotic sorption without the use of labelled P (radioisotope). An SRP mass balance showed that the ecosystem switched from a P sink (during effluent inputs) to a P source (when effluent flow ceased). However, 65-70% of SRP was retained during the exposure time and remained sequestered two-weeks after-effluent flow ceased. Batch studies treated with biocide gave unrealistic results, but P uptake rates derived by other methods were highly comparable. Downstream of the effluent input, net P uptake by algae, bacteria and sediment (including the biofilm polysaccharide matrix) were 0.2 (+/-0.1), 0.4 (+/-0.3), and 1.0 (+/-0.9) mmol m(-2) day(-1) during effluent exposure. While autotrophic production did not respond to the effluent exposure, heterotrophic production increased by 67% relative to the control and this translated into a 50% increase in biological P uptake rate. Therefore, both biological and abiotic components of stream ecosystems uptake P during exposure to treated sewage effluent P inputs, and maintain a long 'memory' of this input in terms of P storage for considerable timescales after loading. (c) 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20619439     DOI: 10.1016/j.watres.2010.06.014

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  2 in total

1.  Phosphorus removal from the hyper-eutrophic Lake Caohai (China) with large-scale water hyacinth cultivation.

Authors:  Yingying Zhang; Haiqin Liu; Shaohua Yan; Xuezheng Wen; Hongjie Qin; Zhi Wang; Zhiyong Zhang
Journal:  Environ Sci Pollut Res Int       Date:  2019-03-20       Impact factor: 4.223

2.  Using high-frequency phosphorus monitoring for water quality management: a case study of the upper River Itchen, UK.

Authors:  Gary R Fones; Adil Bakir; Janina Gray; Lauren Mattingley; Nick Measham; Paul Knight; Michael J Bowes; Richard Greenwood; Graham A Mills
Journal:  Environ Monit Assess       Date:  2020-02-18       Impact factor: 2.513

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.