Literature DB >> 20616401

Exact algebraization of the signal equation of spoiled gradient echo MRI.

Henning Dathe1, Gunther Helms.   

Abstract

The Ernst equation for Fourier transform nuclear magnetic resonance (MR) describes the spoiled steady-state signal created by periodic partial excitation. In MR imaging (MRI), it is commonly applied to spoiled gradient-echo acquisition in the steady state, created by a small flip angle alpha at a repetition time TR much shorter than the longitudinal relaxation time T(1). We describe two parameter transformations of alpha and TR/T(1), which render the Ernst equation as a low-order rational function. Computer algebra can be readily applied for analytically solving protocol optimization, as shown for the dual flip angle experiment. These transformations are based on the half-angle tangent substitution and its hyperbolic analogue. They are monotonic and approach identity for small alpha and small TR/T(1) with a third-order error. Thus, the exact algebraization can be readily applied to fast gradient echo MRI to yield a rational approximation in alpha and TR/T(1). This reveals a fundamental relationship between the square of the flip angle and TR/T(1) which characterizes the Ernst angle, constant degree of T(1)-weighting and the influence of the local radio-frequency field.

Mesh:

Year:  2010        PMID: 20616401     DOI: 10.1088/0031-9155/55/15/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Evaluation of intervertebral disc cartilaginous endplate structure using magnetic resonance imaging.

Authors:  Sung M Moon; Jonathon H Yoder; Alexander C Wright; Lachlan J Smith; Edward J Vresilovic; Dawn M Elliott
Journal:  Eur Spine J       Date:  2013-05-15       Impact factor: 3.134

2.  Measurement of T1 relaxation time of osteochondral specimens using VFA-SWIFT.

Authors:  Mikko J Nissi; Lauri J Lehto; Curtis A Corum; Djaudat Idiyatullin; Jutta M Ellermann; Olli H J Gröhn; Miika T Nieminen
Journal:  Magn Reson Med       Date:  2014-08-08       Impact factor: 4.668

3.  Quantifying iron-oxide nanoparticles at high concentration based on longitudinal relaxation using a three-dimensional SWIFT Look-Locker sequence.

Authors:  Jinjin Zhang; Ryan Chamberlain; Michael Etheridge; Djaudat Idiyatullin; Curtis Corum; John Bischof; Michael Garwood
Journal:  Magn Reson Med       Date:  2014-03-24       Impact factor: 4.668

4.  Unified segmentation based correction of R1 brain maps for RF transmit field inhomogeneities (UNICORT).

Authors:  Nikolaus Weiskopf; Antoine Lutti; Gunther Helms; Marianne Novak; John Ashburner; Chloe Hutton
Journal:  Neuroimage       Date:  2010-10-18       Impact factor: 6.556

5.  Identification of signal bias in the variable flip angle method by linear display of the algebraic Ernst equation.

Authors:  Gunther Helms; Henning Dathe; Nikolaus Weiskopf; Peter Dechent
Journal:  Magn Reson Med       Date:  2011-03-22       Impact factor: 4.668

6.  Imperfect spoiling in variable flip angle T1 mapping at 7T: Quantifying and minimizing impact.

Authors:  Nadège Corbin; Martina F Callaghan
Journal:  Magn Reson Med       Date:  2021-03-01       Impact factor: 3.737

7.  Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual-vendor reproducibility and repeatability study.

Authors:  Tobias Leutritz; Maryam Seif; Gunther Helms; Rebecca S Samson; Armin Curt; Patrick Freund; Nikolaus Weiskopf
Journal:  Hum Brain Mapp       Date:  2020-07-08       Impact factor: 5.399

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.