Literature DB >> 20615593

Comparison between two-dimensional and midsagittal three-dimensional cephalometric measurements of dry human skulls.

Janalt Damstra1, Zacharias Fourie, Yijin Ren.   

Abstract

The aim of this study was to compare two- and three-dimensional cephalometric values by using a three-dimensional analysis based on the midsagittal plane. Spherical metal markers were fixed on to the anatomical landmarks of 10 human skulls, which were examined radiographically with conventional lateral cephalograms and cone-beam computed tomographic (CBCT) scans. Preprogrammed analyses calculated the 18 angular and linear two- and three-dimensional cephalometric values. An error study was made to assess the accuracy and reliability of the methods used. Both sets of values were compared using Wilcoxon's signed-rank test. Probabilities of less than 0.05 were accepted as significant. Reliability of the measurements was assessed by intraclass correlation coefficients (ICC) based on absolute agreement. The method error (ME) was tiny (mean ME<0.61 measuring unit) and reliable (ICC>0.97). Comparison of the two- and three-dimensional measurements showed that that they were reliable (ICC>0.88) and that there were no significant differences (P=0.41-1.00). The values from the cephalometric analyses were comparable and interchangeable when using the midsagittal three-dimensional approach as described.
Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20615593     DOI: 10.1016/j.bjoms.2010.06.006

Source DB:  PubMed          Journal:  Br J Oral Maxillofac Surg        ISSN: 0266-4356            Impact factor:   1.651


  4 in total

1.  Accuracy assessment of the axial images obtained from cone beam computed tomography.

Authors:  Francine Kühl Panzarella; J L C Junqueira; L B Oliveira; N S de Araújo; C Costa
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

2.  Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements.

Authors:  Pil-Kyo Jung; Gung-Chol Lee; Cheol-Hyun Moon
Journal:  Korean J Orthod       Date:  2015-11-20       Impact factor: 1.372

3.  Clinical Radiographic Evaluation of 3Mixtatin and MTA in Primary Teeth Pulpotomies: A Randomized Controlled.

Authors:  Rakesh K Chak; Rajeev K Singh; Jhansi Mutyala; Nidesh K Killi
Journal:  Int J Clin Pediatr Dent       Date:  2022

Review 4.  Cone-Beam Computed Tomography in Orthodontics.

Authors:  Ahmad Abdelkarim
Journal:  Dent J (Basel)       Date:  2019-09-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.