Literature DB >> 20610300

Salivary calculus diagnosis with 3-dimensional cone-beam computed tomography.

Timo Dreiseidler1, Lutz Ritter, Daniel Rothamel, Jörg Neugebauer, Martin Scheer, Robert A Mischkowski.   

Abstract

OBJECTIVE: The objective of this study was to evaluate cone-beam CT (CBCT) diagnoses of sialoliths in the major salivary glands. STUDY
DESIGN: Twenty-nine CBCT images containing salivary calculi were retrospectively evaluated for image quality and artifact influence. Additionally, the reproducibility of calculus measurement and the differences between CBCT measurements and ultrasonography (US) and histomorphometry (HM) measurements were determined. Diagnostic sensitivity and specificity calculations were based on the observations of 3 masked clinicians, who reviewed a total of 58 CBCT volumes.
RESULTS: Salivary calculi were sufficiently visualized in all patients. Metal artifacts were detected in images of 7 patients, and movement artifacts in 2. CBCT calculi measurements were highly reproducible, with mean differences of less than 350 microm. Mean CBCT measurements of calculi diameters differed from mean US measurements by approximately 500 microm and differed from mean HM measurements by approximately 1 mm. For calculus diagnoses, the mean sensitivity and specificity were both 98.85%.
CONCLUSION: Although poor image qualities and artifacts can reduce diagnostic information, salivary calculi can be evaluated adequately with CBCT. CBCT measurements of calculi are highly reproducible and differ little from measurements made with US and HM. Diagnostic sensitivity and specificity levels with CBCT are as high as or higher than those obtained with other diagnostic methods. Because of its high diagnostic-information-to-radiation-dose ratio, CBCT is the preferable imaging modality for salivary calculus diagnosis. Copyright (c) 2010 Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20610300     DOI: 10.1016/j.tripleo.2010.03.013

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  4 in total

1.  A comparative study of the diagnostic capabilities of 2D plain radiograph and 3D cone beam CT sialography.

Authors:  F M Jadu; E W N Lam
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

2.  "Is Cone Beam Computed Tomography (CBCT) a Potential Imaging Tool in ENT Practice?: A Cross-Sectional Survey Among ENT Surgeons in the State of Odisha, India.

Authors:  S Lata; S K Mohanty; S Vinay; Abhaya Chandra Das; Sanjib Das; Priyadarshini Choudhury
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2017-08-05

3.  Interobserver and intraobserver variability in the radiological assessment of sialolithiasis using cone beam computed tomography.

Authors:  L-J Beumer; E-H van der Meij; J-I Kamstra; J-G de Visscher
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2022-01-01

4.  3D Rapid Prototyping for Otolaryngology-Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling.

Authors:  Harley H L Chan; Jeffrey H Siewerdsen; Allan Vescan; Michael J Daly; Eitan Prisman; Jonathan C Irish
Journal:  PLoS One       Date:  2015-09-02       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.