Bhabatosh Mandal1, Niladri Ghosh.
Abstract
A selective method has been developed for the extraction chromatographic separation of Bi(III) with Versatic 10 coated on silanized silica gel (SSG). Bi(III) has been quantitatively extracted from 0.1 M acetate buffer at the range of pH 5.0-5.5. The result showed that the solution pH, influent volume, flow-rate and solution temperature would affect the sorption of Bi(III). The sorbed Bi(III) was eluted with 0.1 M H(2)SO(4). The extractor system has got good values of exchange capacity (1.42 meq. of H(+) g(-1) of dry exchanger at 25 degrees C), break-through capacity (19.75 mg g(-1) at pH 5.5) and column efficiencies (300) with respect to Bi(III). The positive value of DeltaH (12.63 kJ mol(-1)) and DeltaS (0.271 kJ mol(-1) K(-1)) and negative value of DeltaG (-68.241 kJ mol(-1)) indicated that the sorption process was endothermic, entropy gaining and spontaneous in nature. P.F. has been optimized at 76.4+/-0.3 and the desorption constants K(desorption) (8x10(-3)) and K'(desorption) (1.4x10(-1)) have been determined. R(f) values and selectivity factors for diverse metal ions with respect to that of Bi(III) have been determined by ion-exchange paper chromatography. Bi(III) has been separated from synthetic mixtures containing its congeners and other metal ions associated with it in ores and alloy samples. The method was found effective for removal of Bi(III) from different water samples. A plausible mechanism for the extraction of Bi(III) has been suggested. 2010 Elsevier B.V. All rights reserved.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20609513 DOI: 10.1016/j.jhazmat.2010.06.041