Literature DB >> 20608146

Efficacy and safety of the haemostasis achieved by Vivostat system during laparoscopic partial nephrectomy.

Stefano Gidaro1, Luca Cindolo, Katja Lipsky, Richard Zigeuner, Luigi Schips.   

Abstract

INTRODUCTION: Haemostasis remains the greatest challenge during laparoscopic partial nephrectomy. We describe the use of the Vivostat system helping effective haemostasis during laparoscopic partial nephrectomy (LPN). PATIENTS AND
METHOD: Twenty-eight patients underwent LPN. Autologous fibrin sealant was prepared with the Vivostat system and applied to the resection bed. This system is an automated medical device for the preparation of an autologous fibrin sealant from the patient's blood. Pre and postoperative clinical parameters and laboratory values were evaluated, for acute and delayed bleeding.
RESULTS: Median patient's age was 58 years (range, 25-75). All patients underwent LPN for renal tumors (mean size 2.5 cm; range 0.9-4.5 cm). Six resection were performed without vessels clamping, and 22 were realized with selective arterial Bulldog clamping. Haemostasis was achieved by a cellulose bolster (80%), by stitches (67%) and by sealant application after declamping (100%) (mean amount applied: 5.1 ml). The mean warm ischemia time was 26 minutes (range, 16-45) for 22 interventions. Mean blood loss was 128 cc (range, 20-500). Pre-operative and post-operative creatinine values (mean, 0.91 vs. 1 ng/mi) did not differ significantly; whereas mean Hb levels slightly decreases after surgery (mean, 14.7 vs. 12.5 g/dl). Mean operative time was 131 minutes (range, 60-190). All but one had negative surgical margins. One intraoperative bleeding occurred needing blood transfusion (1 unit). Postoperatively, we observed only 1 perirenal hematoma treated conservatively requiring blood transfusion.
CONCLUSIONS: In this study, an effective haemostasis was achieved and maintained after kidney reperfusion. These data support the previous finding with the same system and encourage its use in LPN.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20608146

Source DB:  PubMed          Journal:  Arch Ital Urol Androl        ISSN: 1124-3562


  2 in total

1.  A review of current hemostatic agents and tissue sealants used in laparoscopic partial nephrectomy.

Authors:  I Galanakis; N Vasdev; N Soomro
Journal:  Rev Urol       Date:  2011

2.  Autologous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part I: Intracranial surgical procedure.

Authors:  Francesca Graziano; Francesco Certo; Luigi Basile; Rosario Maugeri; Giovanni Grasso; Flavia Meccio; Mario Ganau; Domenico G Iacopino
Journal:  Surg Neurol Int       Date:  2015-05-12