Literature DB >> 20607510

[Implant-free anterior cruciate ligament reconstruction with the patella ligament and press-fit double bundle technique].

P Hertel1, H Behrend.   

Abstract

Anterior cruciate ligament (ACL) reconstruction using autologous tendons (BTB patellar tendon, hamstrings, quadriceps tendon) in an implant-free fixation technique is becoming more and more popular due to biological and economical reasons. In 1987 an implant-free press-fit fixation technique of a BTB graft from the medial side of the patellar tendon (via mini-arthrotomy) was introduced and first published during the 4th ESKA Conference 1990 in Stockholm. Special emphasis is given to the anatomical orientation of the BTB graft. During the inside-out femoral press-fit fixation the bone-ligament margin of the graft is placed directly into the femoral insertion line of the natural ACL adapting its double-bundle structure. The graft is fixed by press-fit within the tibial metaphysis and its ligamentous part is secured in the metaphysis by harvested cancellous bone blocks driven into the joint line from the outside. The postoperative regime includes weight-bearing as tolerated and free motion. Out of 159 patients 95 could be seen for follow-up after an average of 10.7 years. The final IKDC knee score revealed 22.1% in group A (very good) and 62.1% in group B (good). The Tegner activity level was 6.8 preinjury and 6.0 postoperatively. The average KT 1,000 side-to-side difference was 1.8 mm. Subjectively no patient complained of instability and 99% of the patients could kneel on hard ground with minimal or no complaints. ACL revision surgery due to graft failure was not necessary in any of the patients. Advantages of the described procedure are a narrow anatomical orientation including the double bundle structure of the ACL, rapid graft incorporation by bone-to-bone healing, lack of bone resorption at the graft-host interface, decreased donor site morbidity, cost-effectiveness and ease of possible revision surgery.

Entities:  

Mesh:

Year:  2010        PMID: 20607510     DOI: 10.1007/s00113-010-1789-5

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  15 in total

1.  Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation.

Authors:  V Martinek; N F Friederich
Journal:  Arthroscopy       Date:  1999-04       Impact factor: 4.772

2.  Comparisons of intraosseous graft healing between the doubled flexor tendon graft and the bone-patellar tendon-bone graft in anterior cruciate ligament reconstruction.

Authors:  F Tomita; K Yasuda; S Mikami; T Sakai; S Yamazaki; H Tohyama
Journal:  Arthroscopy       Date:  2001-05       Impact factor: 4.772

3.  Arthroscopic anterior cruciate ligament reconstruction using the double press- fit technique: an alternative to interference screw fixation.

Authors:  Andreas M Halder; Silke Ludwig; Wolfram Neumann
Journal:  Arthroscopy       Date:  2002 Nov-Dec       Impact factor: 4.772

4.  Femoral press-fit fixation of the hamstring tendons for anterior cruciate ligament reconstruction.

Authors:  Michael Jagodzinski; Vahid Behfar; Christof Hurschler; Knut Albrecht; Christian Krettek; Ulrich Bosch
Journal:  Am J Sports Med       Date:  2004 Oct-Nov       Impact factor: 6.202

5.  Tensile properties of the human femur-anterior cruciate ligament-tibia complex. The effects of specimen age and orientation.

Authors:  S L Woo; J M Hollis; D J Adams; R M Lyon; S Takai
Journal:  Am J Sports Med       Date:  1991 May-Jun       Impact factor: 6.202

6.  Testing for isometry during reconstruction of the anterior cruciate ligament. Anatomical and biomechanical considerations.

Authors:  A A Sapega; R A Moyer; C Schneck; N Komalahiranya
Journal:  J Bone Joint Surg Am       Date:  1990-02       Impact factor: 5.284

7.  Knee laxity measurements after anterior cruciate ligament reconstruction, using either bone-patellar-tendon-bone or hamstring tendon autografts, with special emphasis on comparison over time.

Authors:  Mattias Ahldén; Jüri Kartus; Lars Ejerhed; Jón Karlsson; Ninni Sernert
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-03       Impact factor: 4.342

8.  [2-strip substitution-plasty of the anterior cruciate ligament with the quadriceps tendon].

Authors:  W Blauth
Journal:  Unfallheilkunde       Date:  1984-02

9.  ACL reconstruction using bone-patellar tendon-bone press-fit fixation: 10-year clinical results.

Authors:  P Hertel; H Behrend; T Cierpinski; V Musahl; G Widjaja
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-02-03       Impact factor: 4.342

Review 10.  Anterior cruciate ligament reconstruction using semitendinosus and gracilis tendons, bone patellar tendon, or quadriceps tendon-graft with press-fit fixation without hardware. A new and innovative procedure.

Authors:  Hans H Paessler; Dimitrios S Mastrokalos
Journal:  Orthop Clin North Am       Date:  2003-01       Impact factor: 2.472

View more
  3 in total

1.  The biomechanical strength of a hardware-free femoral press-fit method for ACL bone-tendon-bone graft fixation.

Authors:  M P Arnold; L D Burger; D Wirz; B Goepfert; M T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-07       Impact factor: 4.342

Review 2.  [Rupture of the anterior cruciate ligament. Diagnostics and therapy].

Authors:  W Teske; A Anastisiadis; T Lichtinger; C von Schulze Pellengahr; L V von Engelhardt; T Theodoridis
Journal:  Orthopade       Date:  2010-09       Impact factor: 1.087

3.  [Anatomic reconstruction of the anterior cruciate ligament with the autologous quadriceps tendon. Primary and revision surgery].

Authors:  P Forkel; W Petersen
Journal:  Oper Orthop Traumatol       Date:  2014-02-09       Impact factor: 1.154

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.