Literature DB >> 20607179

Diffusion of water into SU-8 microcantilevers.

Chuanjun Liu1, Ying Liu, Mordechai Sokuler, Daniela Fell, Stephan Keller, Anja Boisen, Hans-Jürgen Butt, Günter K Auernhammer, Elmar Bonaccurso.   

Abstract

We present a method to monitor the diffusion of liquid molecules in polymers. A microdrop of water is deposited by a piezoelectric drop generator onto the upper surface of a cantilever made of SU-8 based photoresist. In response, the cantilever bends in the opposite direction. We find that this bending is mainly caused by the diffusion of water into the cantilever and the consequent swelling of SU-8. Using a one-dimensional diffusion model and assuming a simple swelling law, we qualitatively model the bending of the cantilever during in and out diffusion of water in SU-8. With a more sophisticated finite element model the diffusion coefficient of water in the SU-8 polymer can be determined quantitatively from the dynamics of cantilever bending.

Entities:  

Year:  2010        PMID: 20607179     DOI: 10.1039/c002478c

Source DB:  PubMed          Journal:  Phys Chem Chem Phys        ISSN: 1463-9076            Impact factor:   3.676


  5 in total

1.  Non-aqueous electrophoresis integrated with electrospray ionization mass spectrometry on a thiol-ene polymer-based microchip device.

Authors:  Nan Lu; Nickolaj J Petersen; Andreas C Kretschmann; Jörg P Kutter
Journal:  Anal Bioanal Chem       Date:  2021-05-06       Impact factor: 4.142

2.  AFM Microfluidic Cantilevers as Weight Sensors for Live Single Cell Mass Measurements.

Authors:  Chen-Chi Chien; Jiaxin Jiang; Bin Gong; Tao Li; Angelo Gaitas
Journal:  Meas Sci Technol       Date:  2022-06-07       Impact factor: 2.398

3.  An implantable neural probe with monolithically integrated dielectric waveguide and recording electrodes for optogenetics applications.

Authors:  Fan Wu; Eran Stark; Maesoon Im; Il-Joo Cho; Eui-Sung Yoon; György Buzsáki; Kensall D Wise; Euisik Yoon
Journal:  J Neural Eng       Date:  2013-08-28       Impact factor: 5.379

4.  Demonstration of a Label-Free and Low-Cost Optical Cavity-Based Biosensor Using Streptavidin and C-Reactive Protein.

Authors:  Donggee Rho; Seunghyun Kim
Journal:  Biosensors (Basel)       Date:  2020-12-24

5.  Glassy carbon microneedles-new transdermal drug delivery device derived from a scalable C-MEMS process.

Authors:  Richa Mishra; Bidhan Pramanick; Tapas Kumar Maiti; Tarun Kanti Bhattacharyya
Journal:  Microsyst Nanoeng       Date:  2018-12-17       Impact factor: 7.127

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.