Literature DB >> 20607174

Microstructuring of polymer films for sensitive genotyping by real-time PCR on a centrifugal microfluidic platform.

Maximilian Focke1, Fabian Stumpf, Bernd Faltin, Patrick Reith, Dylan Bamarni, Simon Wadle, Claas Müller, Holger Reinecke, Jacques Schrenzel, Patrice Francois, Daniel Mark, Günter Roth, Roland Zengerle, Felix von Stetten.   

Abstract

We present a novel process flow enabling prototyping of microfluidic cartridges made out of polymer films. Its high performance is proven by implementation of a microfluidic genotyping assay testing 22 DNA samples including clinical isolates from patients infected by methicilin-resistant Staphylococcus aureus (MRSA). The microfluidic cartridges (disks) are fabricated by a novel process called microthermoforming by soft lithography (microTSL). Positive moulds are applied allowing for higher moulding precision and very easy demoulding when compared to conventional microthermoforming. High replication accuracies with geometric disk-to-disk variations of less than 1% are typical. We describe and characterise fabrication and application of microfluidic cartridges with wall thicknesses <188 microm thus enabling efficient thermocycling during real-time polymerase chain reaction (PCR). The microfluidic cartridges are designed for operation in a slightly modified commercial thermocycling instrument. This approach demonstrates new opportunities for both microfluidic developments and well-established laboratory instruments. The microfluidic protocol is controlled by centrifugal forces and divides the liquid sample parallely into independent aliquots of 9.8 microl (CV 3.4%, N = 32 wells). The genotyping assays are performed with pre-stored primers and probes for real-time PCR showing a limit of detection well below 10 copies of DNA per reaction well (N = 24 wells in 3 independent disks). The system was evaluated by 44 genotyping assays comprising 22 DNA samples plus duplicates in a total of 11 disks. The samples contained clinical samples of seven different genotypes of MRSA as well as positive and negative controls. The results are in excellent agreement with the reference in microtubes.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20607174     DOI: 10.1039/c004954a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  24 in total

1.  Supernatant decanting on a centrifugal platform.

Authors:  Chih-Hsin Shih; Chien-Hsing Lu; Wei-Li Yuan; Wei-Ling Chiang; Chia-Hui Lin
Journal:  Biomicrofluidics       Date:  2011-03-30       Impact factor: 2.800

2.  Inexpensive, rapid prototyping of microfluidic devices using overhead transparencies and a laser print, cut and laminate fabrication method.

Authors:  Brandon L Thompson; Yiwen Ouyang; Gabriela R M Duarte; Emanuel Carrilho; Shannon T Krauss; James P Landers
Journal:  Nat Protoc       Date:  2015-05-14       Impact factor: 13.491

3.  Sensitive, microliter PCR with consensus degenerate primers for Epstein Barr virus amplification.

Authors:  Christopher R Phaneuf; Kyudam Oh; Nikita Pak; D Curtis Saunders; Christina Conrardy; James P Landers; Suxiang Tong; Craig R Forest
Journal:  Biomed Microdevices       Date:  2013-04       Impact factor: 2.838

4.  Rapid detection of live methicillin-resistant Staphylococcus aureus by using an integrated microfluidic system capable of ethidium monoazide pre-treatment and molecular diagnosis.

Authors:  Yu-Hsin Liu; Chih-Hung Wang; Jiunn-Jong Wu; Gwo-Bin Lee
Journal:  Biomicrofluidics       Date:  2012-09-10       Impact factor: 2.800

5.  Experimental validation of numerical study on thermoelectric-based heating in an integrated centrifugal microfluidic platform for polymerase chain reaction amplification.

Authors:  Mary Amasia; Seok-Won Kang; Debjyoti Banerjee; Marc Madou
Journal:  Biomicrofluidics       Date:  2013-01-30       Impact factor: 2.800

Review 6.  Toward integrated molecular diagnostic system (i MDx): principles and applications.

Authors:  Seung-Min Park; Andrew F Sabour; Jun Ho Son; Sang Hun Lee; Luke P Lee
Journal:  IEEE Trans Biomed Eng       Date:  2014-05       Impact factor: 4.538

Review 7.  Micro total analysis systems for cell biology and biochemical assays.

Authors:  Michelle L Kovarik; Philip C Gach; Douglas M Ornoff; Yuli Wang; Joseph Balowski; Lila Farrag; Nancy L Allbritton
Journal:  Anal Chem       Date:  2011-10-21       Impact factor: 6.986

8.  Diagnostic tools for tackling febrile illness and enhancing patient management.

Authors:  Konstantinos Mitsakakis; Valérie D'Acremont; Sebastian Hin; Felix von Stetten; Roland Zengerle
Journal:  Microelectron Eng       Date:  2018-10-05       Impact factor: 2.523

9.  Emerging Microtechnologies and Automated Systems for Rapid Bacterial Identification and Antibiotic Susceptibility Testing.

Authors:  Yiyan Li; Xing Yang; Weian Zhao
Journal:  SLAS Technol       Date:  2017-08-29       Impact factor: 3.047

10.  Vacuum/compression valving (VCV) using parrafin-wax on a centrifugal microfluidic CD platform.

Authors:  Wisam Al-Faqheri; Fatimah Ibrahim; Tzer Hwai Gilbert Thio; Jacob Moebius; Karunan Joseph; Hamzah Arof; Marc Madou
Journal:  PLoS One       Date:  2013-03-11       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.