Literature DB >> 20607144

Design of a High Resolution, Monolithic Crystal, PET/MRI Detector with DOI Positioning Capability.

Robert S Miyaoka1, Xiaoli Li, Cate Lockhart, Tom K Lewellen.   

Abstract

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal and is compatible for operation in a MRI scanner to support multimodal anatomic and functional imaging. Our design utilizes a novel sensor on the entrance surface (SES) approach combined with a maximum likelihood positioning algorithm. The sensor will be a two-dimensional array of micro-pixel avalanche photodiodes (MAPD). MAPDs are a new type of solid-state photodetector with Geiger mode operation that can provide signal gain similar to a photomltipiler tube (PMT). In addition, they can be operated in high magnetic fields to support PET/MR imaging. Utilizing a multi-step simulation process, we determined the intrinsic spatial resolution characteristics for a variety of detector configurations. The crystal was always modeled as a 48.8 mm by 48.8 mm by 15 mm monolithic slab of a lutetium-based scintillator. The SES design was evaluated via simulation for three different two-dimensional MAPD array sizes: 8×8 with 5.8×5.8 mm(2) pads; 12×12 with 3.8×3.8 mm(2) pads; and 16×16 with 2.8×2.8 mm(2) pads. To reduce the number of signal channels row-column summing readout was explored for the 12×12 and 16×16 channel array devices. The intrinsic spatial resolution for the 8×8 MAPD array is 0.88 mm FWHM in X and Y, and 1.83 mm FWHM in Z (i.e., DOI). Comparing the results versus using a conventional design with the photosensors on the backside of the crystal, an average improvement of ~24% in X and Y and 20% in Z is achieved. The X, Y intrinsic spatial resolution improved to 0.66 mm and 0.65 mm FWHM for the 12×12 and 16×16 MAPDs using row-column readout. Using the 12×12 and 16×16 arrays also led to a slight improvement in the DOI positioning accuracy.

Entities:  

Year:  2008        PMID: 20607144      PMCID: PMC2895620          DOI: 10.1109/NSSMIC.2008.4774469

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  3 in total

1.  MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging.

Authors:  Yuan-Chuan Tai; Arion F Chatziioannou; Yongfeng Yang; Robert W Silverman; Ken Meadors; Stefan Siegel; Danny F Newport; Jennifer R Stickel; Simon R Cherry
Journal:  Phys Med Biol       Date:  2003-06-07       Impact factor: 3.609

2.  Depth of interaction decoding of a continuous crystal detector module.

Authors:  T Ling; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2007-03-29       Impact factor: 3.609

3.  Development of a single detector ring micro crystal element scanner: QuickPET II.

Authors:  Robert S Miyaoka; Marie L Janes; Kisung Lee; Byungki Park; Paul E Kinahan; Tom K Lewellen
Journal:  Mol Imaging       Date:  2005 Apr-Jun       Impact factor: 4.488

  3 in total
  2 in total

1.  An 8×8 Row-Column Summing Readout Electronics for Preclinical Positron Emission Tomography Scanners.

Authors:  Y C Shih; F W Sun; L R Macdonald; B P Otis; R S Miyaoka; W McDougald; T K Lewellen
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

2.  Simulation study of light transport in laser-processed LYSO:Ce detectors with single-side readout.

Authors:  L Bläckberg; G El Fakhri; H Sabet
Journal:  Phys Med Biol       Date:  2017-10-19       Impact factor: 3.609

  2 in total