Literature DB >> 20605737

Robust CTA lumen segmentation of the atherosclerotic carotid artery bifurcation in a large patient population.

Rashindra Manniesing1, Michiel Schaap, Sietske Rozie, Reinhard Hameeteman, Danijela Vukadinovic, Aad van der Lugt, Wiro Niessen.   

Abstract

We propose and validate a semi-automatic method for lumen segmentation of the carotid bifurcation in computed tomography angiography (CTA). First, the central vessel axis is obtained using path tracking between three user-defined points. Second, starting from this path, the segmentation is automatically obtained using a level set. The cost and speed functions for path tracking and segmentation make use of intensity and homogeneity slice-based image features. The method is validated on a large data set of 234 carotid bifurcations of 129 ischemic stroke patients with atherosclerotic disease. The results are compared to manually obtained lumen segmentations. Parameter optimization is carried out on a subset of 30 representative carotid bifurcations. With the optimized parameter settings the method successfully tracked the central vessel paths in 201 of the remaining 204 bifurcations (99%) which were not part of the training set. Comparison with manually drawn segmentations shows that the average overlap between the method and observers is similar (for the inter-observer set the results were 92% vs. 87% and for the intra-observer set 94% vs. 94%). Therefore the method has potential to replace the manual procedure of lumen segmentation of the atherosclerotic bifurcation in CTA. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20605737     DOI: 10.1016/j.media.2010.05.001

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  4 in total

1.  Carotid vasculature modeling from patient CT angiography studies for interventional procedures simulation.

Authors:  M Freiman; L Joskowicz; N Broide; M Natanzon; E Nammer; O Shilon; L Weizman; J Sosna
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-02-29       Impact factor: 2.924

2.  Accurate model-based segmentation of gynecologic brachytherapy catheter collections in MRI-images.

Authors:  Andre Mastmeyer; Guillaume Pernelle; Ruibin Ma; Lauren Barber; Tina Kapur
Journal:  Med Image Anal       Date:  2017-07-18       Impact factor: 8.545

3.  DWT-based segmentation method for coronary arteries.

Authors:  Shuo-Tsung Chen; Pei-Kai Hung; Muh-Shi Lin; Chao-Yu Huang; Chung-Ming Chen; Tzung-Dau Wang; Wen-Jeng Lee
Journal:  J Med Syst       Date:  2014-05-09       Impact factor: 4.460

4.  Carotid atherosclerotic plaque progression and change in plaque composition over time: a 5-year follow-up study using serial CT angiography.

Authors:  M J van Gils; D Vukadinovic; A C van Dijk; D W J Dippel; W J Niessen; A van der Lugt
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-16       Impact factor: 3.825