Literature DB >> 20605557

Anterior superior iliac spine asymmetry assessment on a novel pelvic model: an investigation of accuracy and reliability.

Bradley A Stovall1, Sejong Bae, Shrawan Kumar.   

Abstract

OBJECTIVE: The purpose of this study was to develop a novel pelvic model and determine the accuracy and the inter- and intraexaminer reliability of anterior superior iliac spine (ASIS) positional asymmetry assessment from both sides of the model by osteopathic predoctoral fellows and osteopathic physicians and to evaluate the effect of training.
METHODS: Five osteopathic predoctoral fellows and 5 osteopathic physicians assessed 13 settings of varied ASIS asymmetry of a novel pelvic model for superior/inferior positional asymmetry from both sides of the model in a random order. Assessment from the right and left sides of the model occurred on 2 separate days. Fellows were trained for a week and retested.
RESULTS: Average interexaminer reliability was greatest from the left side of the model for physicians and from the right side for fellows (physicians: kappa = 0.46, fellows: kappa = 0.37), whereas intraexaminer reliability was greatest from the right in both groups (physicians: kappa = 0.49, fellows: kappa = 0.52). Following training of fellows, interexaminer reliability remained highest from the right side of the model (right: kappa = 0.48, left: kappa = 0.36), whereas intraexaminer reliability was higher from the left side (right: kappa = 0.53, left: kappa = 0.59). Physicians and fellows before training were more accurate from the right side of the model (kappa = 0.56 and kappa = 0.52, respectively). Following training of fellows, accuracy increased from both sides of the model (right: kappa = 0.59, left: kappa = 0.53).
CONCLUSIONS: A novel pelvic model was developed to allow assessment of accuracy and reliability of ASIS asymmetry assessment. Individually, physicians and fellows varied in accuracy and inter-/intraexaminer reliability. Further investigation is warranted to understand the clinical and educational application of these results. Copyright (c) 2010 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20605557      PMCID: PMC2913679          DOI: 10.1016/j.jmpt.2010.05.005

Source DB:  PubMed          Journal:  J Manipulative Physiol Ther        ISSN: 0161-4754            Impact factor:   1.437


  18 in total

1.  The association between static pelvic asymmetry and low back pain.

Authors:  P K Levangie
Journal:  Spine (Phila Pa 1976)       Date:  1999-06-15       Impact factor: 3.468

Review 2.  Are chiropractic tests for the lumbo-pelvic spine reliable and valid? A systematic critical literature review.

Authors:  L Hestbaek; C Leboeuf-Yde
Journal:  J Manipulative Physiol Ther       Date:  2000-05       Impact factor: 1.437

3.  A radiostereometric analysis of the movements of the sacroiliac joints in the reciprocal straddle position.

Authors:  B Sturesson; A Uden; A Vleeming
Journal:  Spine (Phila Pa 1976)       Date:  2000-01-15       Impact factor: 3.468

Review 4.  Clinical tests of the sacroiliac joint. A systematic methodological review. Part 1: Reliability.

Authors:  P van der Wurff; R H Hagmeijer; W Meyne
Journal:  Man Ther       Date:  2000-02

5.  The measurement of observer agreement for categorical data.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-03       Impact factor: 2.571

6.  The reliability of multitest regimens with sacroiliac pain provocation tests.

Authors:  Dirk J Kokmeyer; Peter Van der Wurff; Geert Aufdemkampe; Theresa C M Fickenscher
Journal:  J Manipulative Physiol Ther       Date:  2002-01       Impact factor: 1.437

7.  Interexaminer reliability of eight evaluative dimensions of lumbar segmental abnormality: Part II.

Authors:  P D Boline; M Haas; J J Meyer; K Kassak; C Nelson; J C Keating
Journal:  J Manipulative Physiol Ther       Date:  1993 Jul-Aug       Impact factor: 1.437

Review 8.  Reliability of spinal palpation for diagnosis of back and neck pain: a systematic review of the literature.

Authors:  Michael A Seffinger; Wadie I Najm; Shiraz I Mishra; Alan Adams; Vivian M Dickerson; Linda S Murphy; Sibylle Reinsch
Journal:  Spine (Phila Pa 1976)       Date:  2004-10-01       Impact factor: 3.468

9.  Palpation of the upper thoracic spine: an observer reliability study.

Authors:  Henrik Wulff Christensen; Werner Vach; Kirstin Vach; Claus Manniche; Torben Haghfelt; Lisbet Hartvigsen; Poul Flemming Høilund-Carlsen
Journal:  J Manipulative Physiol Ther       Date:  2002-06       Impact factor: 1.437

10.  Manipulation does not alter the position of the sacroiliac joint. A roentgen stereophotogrammetric analysis.

Authors:  T Tullberg; S Blomberg; B Branth; R Johnsson
Journal:  Spine (Phila Pa 1976)       Date:  1998-05-15       Impact factor: 3.468

View more
  1 in total

1.  Reliability and validity of a new clinical test for assessment of the sacroiliac joint dysfunction.

Authors:  Apurv Shimpi; Renuka Hatekar; Ashok Shyam; Parag Sancheti
Journal:  Hong Kong Physiother J       Date:  2018-03-27
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.