Literature DB >> 20605402

En face view of atrial septal defect by two-dimensional transthoracic echocardiography: comparison to real-time three-dimensional transesophageal echocardiography.

Xinsheng Huang1, Junjun Shen, Yigao Huang, Zhichao Zheng, Hongwen Fei, Yueshuang Hou, Yan Xu, Tao Huang, Wenhui Huang, Caojin Zhang.   

Abstract

BACKGROUND: It is generally believed that three-dimensional (3D) echocardiography can provide unique en face views of atrial septal defects (ASDs), whereas conventional two-dimensional (2D) transthoracic echocardiography (TTE) cannot. The purpose of this study was to develop a special 2D TTE-based en face view of ASDs.
METHODS: En face views of ASDs on 2D TTE were obtained in 415 consecutive adult patients and compared with the results of real-time 3D transesophageal echocardiography in 25 of these patients.
RESULTS: Acceptable en face views of ASDs on 2D TTE were obtained in 80% of patients, in whom secundum ASDs could be adequately imaged in more standard 2D imaging planes. The ability to visualize en face views of ASDs on 2D TTE was inversely related to their sizes (P<.05). The differences in the major and minor dimensions of ASDs between 2D TTE and real-time 3D transesophageal echocardiography were not statistically significant (P>.05). Conventional 2D transthoracic echocardiographic views significantly underestimated ASD size with superior-inferior directional major axis.
CONCLUSION: Two-dimensional TTE can provide en face views of ASDs and their spatial orientations with respect to neighboring structures. This method may provide incremental information to 3D echocardiography in patients with ASDs. Copyright (c) 2010 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20605402     DOI: 10.1016/j.echo.2010.04.016

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  5 in total

Review 1.  Contemporary echocardiographic guiding tools for device closure of interatrial communications.

Authors:  Thomas Bartel; Silvana Müller
Journal:  Cardiovasc Diagn Ther       Date:  2013-03

2.  Atrial septal defect in an elderly woman-a case report.

Authors:  C C Diaconu
Journal:  J Med Life       Date:  2011-02-25

3.  Balloon occlusive diameter of non-circular atrial septal defects in transcatheter closure with amplatzer septal occluder.

Authors:  Kwang Hoon Kim; Jinyoung Song; I-Seok Kang; Sung-A Chang; June Huh; Seung Woo Park
Journal:  Korean Circ J       Date:  2013-10-30       Impact factor: 3.243

Review 4.  Comprehensive understanding of atrial septal defects by imaging studies for successful transcatheter closure.

Authors:  Jinyoung Song
Journal:  Korean J Pediatr       Date:  2014-07-23

5.  Outcome of transcatheter closure of oval shaped atrial septal defect with amplatzer septal occluder.

Authors:  Jinyoung Song; Sang Yoon Lee; Jae Sook Baek; Woo Seub Shim; Eun Young Choi
Journal:  Yonsei Med J       Date:  2013-09       Impact factor: 2.759

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.