Literature DB >> 20605308

Influence of thin mucosal tissues on crestal bone stability around implants with platform switching: a 1-year pilot study.

Tomas Linkevicius1, Peteris Apse, Simonas Grybauskas, Algirdas Puisys.   

Abstract

PURPOSE: The aim of this pilot study was to determine what effect thin mucosal tissues can have on crestal bone stability around implants with platform switching.
MATERIALS AND METHODS: Twelve 2-piece implants, consisting of 6 implants with horizontally matching implant-abutment connection (control) and 6 implants with platform switching (test) were placed in 4 patients. The mean age of the patients was 43 years (range, 37 to 56 yrs). Mucosal tissue thickness at implant sites was measured to be 2 mm or less. Implants were restored with 5 splinted crowns and single 3-unit fixed partial denture. Intraoral radiographs were obtained and crestal bone changes were measured at implant placement and after a 1-year follow-up post-treatment. The statistical significance level was set to P less than .05.
RESULTS: Bone loss around the test implants was 1.81 +/- 0.39 mm on the mesial site and 1.70 +/- 0.35 mm on the distal aspect. Control implants overcame marginal bone resorption equaling 1.60 +/- 0.46 mm on the mesial site and 1.76 +/- 0.45 mm on distal measurement. No statistically significant difference was found between control and test implants either mesially (F([1,10]) = 0.746; P = .408) or distally (F([1,10]) = 0.080; P = .783).
CONCLUSION: Within the limitations of this pilot study it can be concluded that implants with platform switching did not preserve crestal bone better in comparison with implants with traditional implant-abutment connection if, at the time of implant placement, thin mucosal tissues were present. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20605308     DOI: 10.1016/j.joms.2009.08.018

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  16 in total

1.  Gingival biotype revisited-novel classification and assessment tool.

Authors:  Kai R Fischer; Andreas Künzlberger; Nikolaos Donos; Stefan Fickl; Anton Friedmann
Journal:  Clin Oral Investig       Date:  2017-05-27       Impact factor: 3.573

2.  Prosthetic Abutment Height is a Key Factor in Peri-implant Marginal Bone Loss.

Authors:  P Galindo-Moreno; A León-Cano; I Ortega-Oller; A Monje; F Suárez; F ÓValle; S Spinato; A Catena
Journal:  J Dent Res       Date:  2014-03-12       Impact factor: 6.116

3.  Connective tissue graft versus xenogeneic collagen matrix for soft tissue augmentation at implant sites: a randomized-controlled clinical trial.

Authors:  Igor Ashurko; Svetlana Tarasenko; Aleksandr Esayan; Alexandr Kurkov; Karen Mikaelyan; Maxim Balyasin; Anna Galyas; Julia Kustova; Silvio Taschieri; Stefano Corbella
Journal:  Clin Oral Investig       Date:  2022-08-27       Impact factor: 3.606

4.  Variations in vertical mucosal thickness at edentulous ridge according to site and gender measured by cone-beam computed tomography.

Authors:  Motohiro Munakata; Koudai Nagata; Minoru Sanda; Ryota Kawamata; Daisuke Sato; Kikue Yamaguchi
Journal:  Int J Implant Dent       Date:  2021-05-12

5.  Marginal bone response of implants with platform switching and non-platform switching abutments in posterior healed sites: a 1-year prospective study.

Authors:  Yun-Chi Wang; Joseph Y K Kan; Kitichai Rungcharassaeng; Phillip Roe; Jaime L Lozada
Journal:  Clin Oral Implants Res       Date:  2014-01-03       Impact factor: 5.977

6.  Volumetric variation of peri-implant soft tissues in convergent collar implants and crowns using the biologically oriented preparation technique (BOPT).

Authors:  G Cabanes-Gumbau; A Pascual-Moscardó; D Peñarrocha-Oltra; B García-Mira; J Aizcorbe-Vicente; M-A Peñarrocha-Diago
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2019-09-01

Review 7.  Marginal bone loss in relation to platform switching implant insertion depth: An update.

Authors:  Rocío Alonso-González; Amparo Aloy-Prósper; David Peñarrocha-Oltra; M A Peñarrocha-Diago; M Peñarrocha-Diago
Journal:  J Clin Exp Dent       Date:  2012-07-01

Review 8.  Impact of platform switching on marginal peri-implant bone-level changes. A systematic review and meta-analysis.

Authors:  Frank Peter Strietzel; Konrad Neumann; Moritz Hertel
Journal:  Clin Oral Implants Res       Date:  2014-01-20       Impact factor: 5.977

9.  Immediate Loading of Implant-Supported Single Crowns after Conventional and Ultrasonic Implant Site Preparation: A Multicenter Randomized Controlled Clinical Trial.

Authors:  Claudio Stacchi; Teresa Lombardi; Domenico Baldi; Calogero Bugea; Antonio Rapani; Giuseppe Perinetti; Angelo Itri; David Carpita; Guido Audenino; Giuseppe Bianco; Simone Verardi; Stefano Carossa; Gianmario Schierano
Journal:  Biomed Res Int       Date:  2018-08-14       Impact factor: 3.411

10.  Implant success and survival rates in daily dental practice: 5-year results of a non-interventional study using CAMLOG SCREW-LINE implants with or without platform-switching abutments.

Authors:  Sven Marcus Beschnidt; Claudio Cacaci; Kerem Dedeoglu; Detlef Hildebrand; Helfried Hulla; Gerhard Iglhaut; Gerald Krennmair; Markus Schlee; Paul Sipos; Andres Stricker; Karl-Ludwig Ackermann
Journal:  Int J Implant Dent       Date:  2018-11-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.