Literature DB >> 2060336

Heat and moisture exchanger vs heated humidifier during long-term mechanical ventilation. A prospective randomized study.

B Misset1, B Escudier, D Rivara, B Leclercq, G Nitenberg.   

Abstract

Adequate humidification of inspired gases with HMEs during long-term MV remains controversial. In this study, a comparison is made between tracheal secretions during long-term MV either with HME or conventional HH. Both the HME and HH groups were similar with respect to age, sex, diagnosis, duration of MV, SAPS and mortality. Temperature of gases in the tracheal tube was lower and the amount of tracheal instillations was greater in the HME group than in the HH group. Tracheal secretions became thicker between day 1 (control) and day 5, in the HME group than in the HH group. Four and two tube occlusions occurred in HME and HH groups, respectively. Tracheal bacterial colonization was similar in the two groups. Given the advantages of HME (reduced nurses' work and financial cost), HME could be routinely used under cautious surveillance and replaced by HH if difficulty in suctioning occurs.

Entities:  

Mesh:

Year:  1991        PMID: 2060336     DOI: 10.1378/chest.100.1.160

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  4 in total

1.  Use of heat and moisture exchanging (HME) filters in mechanically ventilated ICU patients: influence on airway flow-resistance.

Authors:  M Chiaranda; L Verona; O Pinamonti; L Dominioni; G Minoja; G Conti
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

2.  Ventilator-associated pneumonia using a heated humidifier or a heat and moisture exchanger: a randomized controlled trial [ISRCTN88724583].

Authors:  Leonardo Lorente; María Lecuona; Alejandro Jiménez; María L Mora; Antonio Sierra
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

3.  Mechanical effects of heat-moisture exchangers in ventilated patients.

Authors:  G A Iotti; M C Olivei; A Braschi
Journal:  Crit Care       Date:  1999-09-23       Impact factor: 9.097

Review 4.  Heat and moisture exchangers (HMEs) and heated humidifiers (HHs) in adult critically ill patients: a systematic review, meta-analysis and meta-regression of randomized controlled trials.

Authors:  Maria Vargas; Davide Chiumello; Yuda Sutherasan; Lorenzo Ball; Antonio M Esquinas; Paolo Pelosi; Giuseppe Servillo
Journal:  Crit Care       Date:  2017-05-29       Impact factor: 9.097

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.