Literature DB >> 20602976

Analytical approaches for Hg determination in wastewater samples by means of total reflection X-ray fluorescence spectrometry.

E Marguí1, P Kregsamer, M Hidalgo, J Tapias, I Queralt, C Streli.   

Abstract

At present, there is a considerable interest in Hg monitoring in wastewater samples due to its widespread occurrence and the high toxicity of most of its compounds. Hg determination in water samples by means of total reflection X-ray fluorescence spectrometry (TXRF) entails some difficulties due to the high vapor pressure and low boiling point of this element that produce evaporation and loss of Hg from the surface of the reflector during the drying process, commonly used for sample preparation in TXRF analysis. The main goal of the present research was to develop a fast and simple chemical strategy to avoid Hg volatilization during the analysis of wastewater samples by TXRF spectrometry. Three different analytical procedures were tested for this purpose: (i) increasing the viscosity of the wastewater sample by adding a non-ionic surfactant (Triton X-114), (ii) Hg immobilization on the quartz reflectors using the extractant tri-isobutylphosphine (Cyanex 471X) and (iii) formation of a stable and non-volatile Hg complex into the wastewater sample. The best analytical strategy was found to be the formation of a Hg complex with thiourea (pH=10) before the deposition of 10 microL of sample on the reflector for following TXRF analysis. Analytical figures of merit such as linearity, limits of detection, accuracy and precision were carefully evaluated. Finally, the developed methodology was applied for the determination of Hg in different types of wastewater samples (industrial effluents, municipal effluents from conventional systems and municipal effluents from constructed wetlands). Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20602976     DOI: 10.1016/j.talanta.2010.05.066

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  TXRF analysis of soils and sediments to assess environmental contamination.

Authors:  Fabjola Bilo; Laura Borgese; Davide Cazzago; Annalisa Zacco; Elza Bontempi; Rita Guarneri; Marco Bernardello; Silvia Attuati; Pranvera Lazo; Laura E Depero
Journal:  Environ Sci Pollut Res Int       Date:  2014-12       Impact factor: 4.223

2.  Colorimetric and visual detection of mercury(II) based on the suppression of the interaction of dithiothreitol with agar-stabilized silver-coated gold nanoparticles.

Authors:  Qiang Da; Yuanyuan Gu; Xiafeng Peng; Liying Zhang; Shuhu Du
Journal:  Mikrochim Acta       Date:  2018-07-04       Impact factor: 5.833

3.  Intelligent simultaneous quantitative online analysis of environmental trace heavy metals with total-reflection X-ray fluorescence.

Authors:  Junjie Ma; Yeyao Wang; Qi Yang; Yubing Liu; Ping Shi
Journal:  Sensors (Basel)       Date:  2015-05-06       Impact factor: 3.576

4.  Direct Mercury Detection in Landfill Leachate Using a Novel AuNP-Biopolymer Carbon Screen-Printed Electrode Sensor.

Authors:  Jae-Hoon Hwang; David Fox; Jordan Stanberry; Vasileios Anagnostopoulos; Lei Zhai; Woo Hyoung Lee
Journal:  Micromachines (Basel)       Date:  2021-06-01       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.