Literature DB >> 20602505

Localization of non-palpable breast cancer using a radiolabelled titanium seed.

Y E A van Riet1, F H Jansen, M van Beek, C J H van de Velde, H J T Rutten, G A P Nieuwenhuijzen.   

Abstract

BACKGROUND: Resection guided by a radiologically placed hookwire is the most common surgical technique for non-palpable breast cancer. This technique has several well described disadvantages such as incidental migration, kinking or fracture of the wire, and difficult logistics between the radiology, surgical and nuclear medicine departments. Use of an iodine-125-radiolabelled (I-125) seed for localization of non-palpable breast tumours could potentially prevent these problems.
METHODS: Data on use of the I-125 seed localization technique in 325 consecutive women were collected prospectively between October 2003 and June 2009. All patients with screen-detected, histologically proven malignancy were included. Patients with a preoperative core biopsy showing either ductal carcinoma in situ or unclear pathology were excluded from this study.
RESULTS: The mean(s.d.) age of the women was 59.5(11.9) years. Localization was guided ultrasonographically in 275 procedures, stereotactically in 45 and by both techniques in five. The I-125 seed was removed by surgery after a mean of 4(5) days. The mean duration of operation was 62.9(21.2) min. Complete tumour removal was achieved in 310 procedures (95.4 per cent).
CONCLUSION: Localization of impalpable breast cancer using a I-125 seed was safe and led to a high proportion of radical lumpectomies. Copyright (c) 2010 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20602505     DOI: 10.1002/bjs.7097

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  4 in total

1.  Radioactive seed localisation to guide removal of impalpable lymph nodes (radioguided occult lesion localisation using iodine-125 seeds, "ROLLIS").

Authors:  Lee Jackson; Anita Geraldine Bourke; Farah Abdul Aziz; Donna Taylor
Journal:  BMJ Case Rep       Date:  2014-03-22

2.  A Randomized Prospective Comparison of Patient-Assessed Satisfaction and Clinical Outcomes with Radioactive Seed Localization versus Wire Localization.

Authors:  Erica V Bloomquist; Nicolas Ajkay; Sujata Patil; Abigail E Collett; Thomas G Frazier; Andrea V Barrio
Journal:  Breast J       Date:  2015-12-23       Impact factor: 2.431

3.  Radioactive seed localization compared to wire localization in breast-conserving surgery: initial 6-month experience.

Authors:  James O Murphy; Tracy-Ann Moo; Tari A King; Kimberly J Van Zee; Kristine A Villegas; Michelle Stempel; Anne Eaton; Jean M St Germain; Elizabeth Morris; Monica Morrow
Journal:  Ann Surg Oncol       Date:  2013-08-14       Impact factor: 5.344

Review 4.  Magnetic Resonance Imaging-Guided Breast Interventions: Role in Biopsy Targeting and Lumpectomies.

Authors:  Eva C Gombos; Jayender Jagadeesan; Danielle M Richman; Daniel F Kacher
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-07-08       Impact factor: 2.266

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.