Literature DB >> 20601771

A VMAT planning solution for prostate patients using a commercial treatment planning system.

C J Boylan1, C Golby, C G Rowbottom.   

Abstract

Volumetric modulated arc therapy (VMAT) is a rotational delivery technique which offers the potential of improved dose distributions and shorter treatment times when compared to fixed-beam intensity-modulated radiation therapy (IMRT). This note describes the use of an existing treatment planning system (Philips Pinnacle(3) v.8.0), supplemented by in-house software, to produce a single-arc VMAT prostate plan. While a number of planning systems for the Elekta VMAT platform are commercially available, the use of an in-house solution has allowed more detailed investigations of VMAT planning, as well as greater control over the optimization process. The solution presented here begins with a static step-and-shoot IMRT approach to provide initial segment shapes, which are then modified and sequenced into 60 equally spaced control points in a 360 degrees arc. Dose-volume histogram comparisons demonstrate that this VMAT planning method offers multiple dose level target coverage comparable to that from a standard IMRT approach. The VMAT plans also show superior sparing of critical structures such as the rectum and bladder. Delivery times are reduced with the VMAT method, and the results of dosimetric verification, resilience and repeatability tests indicate that the solution is robust.

Entities:  

Mesh:

Year:  2010        PMID: 20601771     DOI: 10.1088/0031-9155/55/14/N01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  A comprehensive comparison of IMRT and VMAT plan quality for prostate cancer treatment.

Authors:  Enzhuo M Quan; Xiaoqiang Li; Yupeng Li; Xiaochun Wang; Rajat J Kudchadker; Jennifer L Johnson; Deborah A Kuban; Andrew K Lee; Xiaodong Zhang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-07-15       Impact factor: 7.038

2.  A comparison of a moderately hypofractionated IMRT planning technique used in a randomised UK external beam radiotherapy trial with an in-house technique for localised prostate cancer.

Authors:  Ian Gleeson
Journal:  Rep Pract Oncol Radiother       Date:  2020-03-19

3.  Comparison of hybrid volumetric modulated arc therapy (VMAT) technique and double arc VMAT technique in the treatment of prostate cancer.

Authors:  Christopher Amaloo; Daryl P Nazareth; Lalith K Kumaraswamy
Journal:  Radiol Oncol       Date:  2015-08-21       Impact factor: 2.991

4.  Planning for mARC treatments with the Eclipse treatment planning system.

Authors:  Vikren Sarkar; Long Huang; Prema Rassiah-Szegedi; Hui Zhao; Jessica Huang; Martin Szegedi; Bill J Salter
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

5.  Delivery parameter variations and early clinical outcomes of volumetric modulated arc therapy for 31 prostate cancer patients: an intercomparison of three treatment planning systems.

Authors:  Shinichi Tsutsumi; Masako N Hosono; Daisaku Tatsumi; Yoshitaka Miki; Yutaka Masuoka; Ryo Ogino; Kentaro Ishii; Yasuhiko Shimatani; Yukio Miki
Journal:  ScientificWorldJournal       Date:  2013-01-15
  5 in total