R Singh1, P D Lee, J R Jones, G Poologasundarampillai, T Post, T C Lindley, R J Dashwood.
Abstract
We present a novel route for producing a new class of titanium foams for use in biomedical implant applications. These foams are hierarchically porous, with both the traditional large (>300μm) highly interconnected pores and, uniquely, wall struts also containing micron scale (0.5-5μm) interconnected porosities. The fabrication method consists of first producing a porous oxide precursor via a gel casting method, followed by electrochemical reduction to produce a metallic foam. This method offers the unique ability to tailor the porosity at several scales independently, unlike traditional space-holder techniques. Reducing the pressure during foam setting increased the macro-pore size. The intra-strut pore size (and percentage) can be controlled independently of macro-pore size by altering the ceramic loading and sintering temperature during precursor production. Typical properties for an 80% porous Ti foam were a modulus of ∼1GPa, a yield strength of 8MPa and a permeability of 350 Darcies, all of which are in the range required for biomedical implant applications. We also demonstrate that the micron scale intra-strut porosities can be exploited to allow infiltration of bioactive materials using a novel bioactive silica-polymer composite, resulting in a metal-bioactive silica-polymer composite.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20601241 DOI: 10.1016/j.actbio.2010.06.027
Source DB: PubMed Journal: Acta Biomater ISSN: 1742-7061 Impact factor: 8.947