Evaluation of respiratory function in freely moving Beagle dogs using implanted impedance technology.

Kenneth Kearney1, Monica Metea, Teresa Gleason, Timothy Edwards, Philip Atterson.   

Abstract

INTRODUCTION: The Safety Pharmacology ICH S7A guidelines mandate the preclinical evaluation of drug effects on respiratory function. Chronic measurements of potential drug effects are commonly performed in rodents due to lack of a viable alternative in large animals. Presently, although the value and validity of these standard methods cannot be refuted, each method presents inherent limitations; such as the introduction of restraint stress (e.g. head-out rodent plethysmography and the pneumotachograph-equipped dog face mask), or sensitivity issues (e.g. whole body plethysmography). Since these approaches may limit the number of time points tested or affect respiratory parameters, new and accurate methods are needed for assessing respiratory function in conscious, freely moving animals.
METHODS: We evaluated a new surgically implanted telemetry device, which adds an impedance sensor for the chronic measurement of respiratory parameters to the standard device used for safety pharmacology cardiovascular studies. The feasibility of the implantable device was assessed based on concordance of respiratory data with pneumotachograph-recorded parameters in conscious Beagle dogs following intravenous administration of a positive control (4 mg/kg doxapram).
RESULTS: Linear regression analysis of data collected under restrained conditions showed a high correlation (R(2) 0.95) between impedance-derived respiratory parameters (tidal volume and respiratory frequency) and direct measurements of respiration via pneumotachograph. The correlation was reproduced when animals were challenged under the same dosing regimen. Volume changes similar to those obtained during the restrained collection were observed during the ambulatory collection following doxapram administration. Calibration of impedance-based values was adequate using both individual and population-based baseline conversion factors, both approximating actual mean respiratory variables collected with the pneumotachograph. DISCUSSION: The benefit of this model is the accurate, continuous measurement of respiratory endpoints in restrained, as well as ambulatory settings. Assessment of multiple physiological parameters collected concurrently and the use of population-based calibrations may enable the maximization of resources and shortened timelines in drug development. 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20601021     DOI: 10.1016/j.vascn.2010.06.004

Source DB:  PubMed          Journal:  J Pharmacol Toxicol Methods        ISSN: 1056-8719            Impact factor:   1.950


  2 in total

1.  An Impedance-Based Model for the Assessment of Cardiopulmonary Function in Rabbits.

Authors:  Michael S Horsmon; Nicole M Vincelli; James T Taylor; Robert L Kristovich
Journal:  J Am Assoc Lab Anim Sci       Date:  2016-03       Impact factor: 1.232

2.  Effects of Anisodine Hydrobromide on the Cardiovascular and Respiratory Functions in Conscious Dogs.

Authors:  Yunlu Liu; Lin Wang; Feng Wan; Na Yang
Journal:  Drug Des Devel Ther       Date:  2020-10-13       Impact factor: 4.162

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.