Literature DB >> 20599965

A geometric morphometric assessment of the optic cup in glaucoma.

Paul G Sanfilippo1, Andrea Cardini, Ian A Sigal, Jonathan B Ruddle, Brian E Chua, Alex W Hewitt, David A Mackey.   

Abstract

The morphologic appearance of the optic disc is of interest in glaucoma. In contrast to descriptive classification systems that are currently used, a quantitative approach to the analysis of optic disc morphology is required. Our goal was to determine the optimal method for quantifying optic cup shape by comparing traditional (ovality, form-factor and neuroretinal rim (NRR) width ratio) and geometric morphometric approaches. Left optic disc stereophotographs of 160 (80 normal and 80 glaucomatous (stratified by severity)) subjects were examined. The optic cup margins were stereoscopically delineated with a custom tracing system and saved as a series of discrete points. The geometric morphometric methods of elliptic Fourier analysis (EFA) and sliding semi-landmark analysis (SSLA) were used to eliminate variation unrelated to shape (e.g. size) and yield a series of shape variables. Differences in optic cup shape between normal and glaucoma groups were investigated. Discriminant functions were computed and the sensitivity and specificity of each technique determined. Receiver operator characteristic (ROC) curves were calculated for all methods and evaluated in their potential to discriminate between normal and glaucomatous eyes based on the shape variables. All geometric morphometric methods revealed differences between normal and glaucomatous eyes in optic cup shape, in addition to the traditional parameters of ovality, form-factor and NRR width ratio (p<0.0005). SSLA (minimum bending energy criterion--18 points) had the best sensitivity (83%) and area under the curve (AUC) (0.91). EFA (72 points) performed similarly well (74%, 0.89) as did the set of traditional shape-based variables (76%, 0.86). This study demonstrated that a geometric morphometric approach for discriminating between normal and glaucomatous eyes in optic cup shape is superior to that provided by traditional single parameter shape measures. Such analytical techniques could be incorporated into future automated optic disc screening modalities. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20599965     DOI: 10.1016/j.exer.2010.06.014

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  4 in total

1.  The application of traditional and geometric morphometric analyses for forensic quantification of sexual dimorphism: preliminary investigations in a Western Australian population.

Authors:  Daniel Franklin; Andrea Cardini; Ambika Flavel; Algis Kuliukas
Journal:  Int J Legal Med       Date:  2012-03-08       Impact factor: 2.686

2.  IOP-induced lamina cribrosa displacement and scleral canal expansion: an analysis of factor interactions using parameterized eye-specific models.

Authors:  Ian A Sigal; Hongli Yang; Michael D Roberts; Claude F Burgoyne; J Crawford Downs
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-03-30       Impact factor: 4.799

3.  Stereo Photo Measured ONH Shape Predicts Development of POAG in Subjects With Ocular Hypertension.

Authors:  Mark Christopher; Michael D Abràmoff; Li Tang; Mae O Gordon; Michael A Kass; Donald L Budenz; John H Fingert; Todd E Scheetz
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-07       Impact factor: 4.799

4.  Shape analysis of the peripapillary RPE layer in papilledema and ischemic optic neuropathy.

Authors:  Patrick Sibony; Mark J Kupersmith; F James Rohlf
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-10-10       Impact factor: 4.799

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.