Literature DB >> 20599288

General bounds for electrode mislocation on the EEG inverse problem.

L Beltrachini1, N von Ellenrieder, C H Muravchik.   

Abstract

We analyze the effect of electrode mislocation on the electroencephalography (EEG) inverse problem using the Cramér-Rao bound (CRB) for single dipolar source parameters. We adopt a realistic head shape model, and solve the forward problem using the Boundary Element Method; the use of the CRB allows us to obtain general results which do not depend on the algorithm used for solving the inverse problem. We consider two possible causes for the electrode mislocation, errors in the measurement of the electrode positions and an imperfect registration between the electrodes and the scalp surfaces. For 120 electrodes placed in the scalp according to the 10-20 standard, and errors on the electrode location with a standard deviation of 5mm, the lower bound on the standard deviation in the source depth estimation is approximately 1mm in the worst case. Therefore, we conclude that errors in the electrode location may be tolerated since their effect on the EEG inverse problem are negligible from a practical point of view.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Mesh:

Year:  2010        PMID: 20599288     DOI: 10.1016/j.cmpb.2010.05.008

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  10 in total

1.  Increasing the accuracy of electromagnetic inverses using functional area source correlation constraints.

Authors:  Benoit R Cottereau; Justin M Ales; Anthony M Norcia
Journal:  Hum Brain Mapp       Date:  2011-09-21       Impact factor: 5.038

2.  Smartphone-based photogrammetry provides improved localization and registration of scalp-mounted neuroimaging sensors.

Authors:  Ilaria Mazzonetto; Marco Castellaro; Robert J Cooper; Sabrina Brigadoi
Journal:  Sci Rep       Date:  2022-06-27       Impact factor: 4.996

Review 3.  Personalized tDCS for Focal Epilepsy-A Narrative Review: A Data-Driven Workflow Based on Imaging and EEG Data.

Authors:  Steven Beumer; Paul Boon; Debby C W Klooster; Raymond van Ee; Evelien Carrette; Maarten M Paulides; Rob M C Mestrom
Journal:  Brain Sci       Date:  2022-05-07

4.  Accuracy of high-density EEG electrode position measurement using an optical scanner compared with the photogrammetry method.

Authors:  Orsolya Györfi; Cheng-Teng Ip; Anders Bach Justesen; Maria Louise Gam-Jensen; Connie Rømer; Martin Fabricius; Lars H Pinborg; Sándor Beniczky
Journal:  Clin Neurophysiol Pract       Date:  2022-05-02

5.  Photogrammetry-Based Head Digitization for Rapid and Accurate Localization of EEG Electrodes and MEG Fiducial Markers Using a Single Digital SLR Camera.

Authors:  Tommy Clausner; Sarang S Dalal; Maité Crespo-García
Journal:  Front Neurosci       Date:  2017-05-16       Impact factor: 4.677

6.  Source localization of epileptic spikes using Multiple Sparse Priors.

Authors:  Mariano Fernandez-Corazza; Rui Feng; Chengxin Ma; Jie Hu; Li Pan; Phan Luu; Don Tucker
Journal:  Clin Neurophysiol       Date:  2020-12-03       Impact factor: 3.708

7.  Consequences of EEG electrode position error on ultimate beamformer source reconstruction performance.

Authors:  Sarang S Dalal; Stefan Rampp; Florian Willomitzer; Svenja Ettl
Journal:  Front Neurosci       Date:  2014-03-11       Impact factor: 4.677

8.  More Reliable EEG Electrode Digitizing Methods Can Reduce Source Estimation Uncertainty, but Current Methods Already Accurately Identify Brodmann Areas.

Authors:  Seyed Yahya Shirazi; Helen J Huang
Journal:  Front Neurosci       Date:  2019-11-06       Impact factor: 4.677

9.  Optimal design of on-scalp electromagnetic sensor arrays for brain source localisation.

Authors:  Leandro Beltrachini; Nicolas von Ellenrieder; Roland Eichardt; Jens Haueisen
Journal:  Hum Brain Mapp       Date:  2021-07-10       Impact factor: 5.038

10.  Using the MoBI motion capture system to rapidly and accurately localize EEG electrodes in anatomic space.

Authors:  Kevin A Mazurek; Eleni Patelaki; John J Foxe; Edward G Freedman
Journal:  Eur J Neurosci       Date:  2021-02-21       Impact factor: 3.698

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.