Literature DB >> 20593370

Simultaneous quantification of T2 and T'2 using a combined gradient echo-spin echo sequence at ultrahigh field.

Eleanor F Cox1, Penny A Gowland.   

Abstract

Measuring T(2) at 7.0 T is not trivial due to RF inhomogeneity effects, however, gradient echo sampling of a spin echo is insensitive to RF pulse errors, does not suffer from significant distortions, and allows T'(2) and T(2) to be estimated simultaneously. Gradient echo sampling of a spin echo results are relatively sensitive to noise and therefore fitting methods and timing parameters were optimized: a weighted linear fit reduced the errors in T(2) compared to a nonlinear fit, the optimum spin echo time was approximately equal to the expected T(2) and decreasing the number of gradient echoes minimized the error of the estimated T(2). T(2), T'(2), and T*(2) decreased with field strength in frontal gray matter, occipital gray matter, and white matter, with T(2) having a linear dependence (frontal gray matter: 87, 76, 47 ms, occipital gray matter: 80, 68, 46 ms and white matter: 80, 71, 47 ms at 1.5, 3.0 and 7.0 T, respectively).
Copyright © 2010 Wiley-Liss, Inc.

Mesh:

Year:  2010        PMID: 20593370     DOI: 10.1002/mrm.22522

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Gradient echo plural contrast imaging--signal model and derived contrasts: T2*, T1, phase, SWI, T1f, FST2*and T2*-SWI.

Authors:  Jie Luo; Bharathi D Jagadeesan; Anne H Cross; Dmitriy A Yablonskiy
Journal:  Neuroimage       Date:  2012-01-28       Impact factor: 6.556

2.  Modeling and suppression of respiration induced B0-fluctuations in non-balanced steady-state free precession sequences at 7 Tesla.

Authors:  Pål Erik Goa; Benedikt Andreas Poser; Markus Barth
Journal:  MAGMA       Date:  2012-09-25       Impact factor: 2.310

3.  Human brain iron mapping using atlas-based T2 relaxometry.

Authors:  Khader M Hasan; Indika S Walimuni; Larry A Kramer; Ponnada A Narayana
Journal:  Magn Reson Med       Date:  2011-06-23       Impact factor: 4.668

4.  NODDI reproducibility and variability with magnetic field strength: A comparison between 1.5 T and 3 T.

Authors:  Ai Wern Chung; Kiran K Seunarine; Chris A Clark
Journal:  Hum Brain Mapp       Date:  2016-08-01       Impact factor: 5.038

5.  A SEmi-Adiabatic matched-phase spin echo (SEAMS) PINS pulse-pair for B1 -insensitive simultaneous multislice imaging.

Authors:  Rebecca E Feldman; Haisam M Islam; Junqian Xu; Priti Balchandani
Journal:  Magn Reson Med       Date:  2015-03-10       Impact factor: 4.668

6.  Semi-adiabatic Shinnar-Le Roux pulses and their application to diffusion tensor imaging of humans at 7T.

Authors:  Priti Balchandani; Deqiang Qiu
Journal:  Magn Reson Imaging       Date:  2014-04-13       Impact factor: 2.546

Review 7.  Ultra-High-Field MR Neuroimaging.

Authors:  P Balchandani; T P Naidich
Journal:  AJNR Am J Neuroradiol       Date:  2014-12-18       Impact factor: 3.825

8.  In vivo quantification of T₂ anisotropy in white matter fibers in marmoset monkeys.

Authors:  Pascal Sati; Afonso C Silva; Peter van Gelderen; Maria I Gaitan; Jillian E Wohler; Steven Jacobson; Jeff H Duyn; Daniel S Reich
Journal:  Neuroimage       Date:  2011-08-27       Impact factor: 6.556

9.  T2*-based fiber orientation mapping.

Authors:  Jongho Lee; Peter van Gelderen; Li-Wei Kuo; Hellmut Merkle; Afonso C Silva; Jeff H Duyn
Journal:  Neuroimage       Date:  2011-04-22       Impact factor: 6.556

10.  GESFIDE-PROPELLER approach for simultaneous R2 and R2* measurements in the abdomen.

Authors:  Ning Jin; Yang Guo; Zhuoli Zhang; Longjiang Zhang; Guangming Lu; Andrew C Larson
Journal:  Magn Reson Imaging       Date:  2013-09-14       Impact factor: 2.546

View more