Literature DB >> 20588991

Analysis and identification of phase error in phase measuring profilometry.

Feng Chen1, Xianyu Su, Liqun Xiang.   

Abstract

Both the analysis of phase errors which occur at the abrupt discontinuities in phase measuring profilometry (PMP) and the identification method are presented in this paper. The sampling effect of CCD will cause a dilution of accuracy in PMP, especially at abrupt discontinuities on the object surface. The existing methods cannot efficiently identify the abrupt discontinuities. We analyze the relationship between the phase, the height and the equivalent wavelength. By viewing the phase as the argument of a vector we find out that CCD sampling introduces errors into the measurement and the phase is nonlinear to the equivalent wavelength at the abrupt discontinuities. Therefore temporal phase unwrapping (TPU) is introduced into the measurement to identify the abrupt discontinuities. Computer simulations and practical experiment validate the feasibility of this method.

Entities:  

Mesh:

Year:  2010        PMID: 20588991     DOI: 10.1364/OE.18.011300

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  2 in total

1.  Improved 3D measurement with a novel preprocessing method in DFP.

Authors:  Yi Xiao; You-Fu Li
Journal:  Robotics Biomim       Date:  2017-11-17

2.  Application of Moire Profilometry in Three-Dimensional Profile Reconstruction of Key Parts in Railway.

Authors:  Ruyu Ma; Jinlong Li; Kailang He; Tao Tang; Yu Zhang; Xiaorong Gao
Journal:  Sensors (Basel)       Date:  2022-03-24       Impact factor: 3.576

  2 in total