Daniel H Broaddus1, Mark A Foster, Onur Kuzucu, Amy C Turner-Foster, Karl W Koch, Michal Lipson, Alexander L Gaeta.
Abstract
We demonstrate a temporal imaging system based on parametric mixing that allows simple triggering from an external clock by using a time-lens-based pump laser. We integrate our temporal imaging system into a time-to-frequency measurement scheme and demonstrate the ability to perform characterization of temporal waveforms with 1.4-ps resolution and a 530-ps record length. We also integrate our system into a temporal-magnification scheme and demonstrate single-shot operation with a 113 x magnification factor, 1.5-ps resolution, and 220-ps record length.Mesh:
Year: 2010 PMID: 20588561 DOI: 10.1364/OE.18.014262
Source DB: PubMed Journal: Opt Express ISSN: 1094-4087 Impact factor: 3.894