Literature DB >> 20588529

Full-range polarization-sensitive swept-source optical coherence tomography by simultaneous transversal and spectral modulation.

Masahiro Yamanari1, Shuichi Makita, Yiheng Lim, Yoshiaki Yasuno.   

Abstract

Polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) is used to measure three-dimensional phase-retardation images of birefringent biological tissue in vivo. PS-SS-OCT with continuous source polarization modulation is used to multiplex the incident states of polarization in the signal frequency of each A-scan. Although it offers the advantage of measurement speed that is as high as that of standard SS-OCT, its disadvantage is low axial measurement range. To overcome this drawback, we employed the B-M-mode scan (BM-scan) method, which removes complex conjugate ambiguity by applying phase modulation along the transversal scanning direction. Since polarization modulation and BM-scan are applied in different scanning directions, these methods can be combined to make the optimum use of both full range and polarization-sensitive imaging. Phase fluctuations that cause measurement failure were numerically canceled before demodulating the B-scan oriented modulation. After removing complex conjugate artifacts, the axial measurement range was 5.35 mm, and the signal-to-conjugate ratio was 40.5 dB. We demonstrated retinal imaging using the PS-SS-OCT system with a frequency-swept laser at a center wavelength of 1064 nm and an axial resolution of 11.4 microm in tissue. Full-range polarization-sensitive retinal images showed characteristic birefringence of fibrous tissues such as retinal nerve fiber, sclera, and lamina cribrosa.

Entities:  

Mesh:

Year:  2010        PMID: 20588529     DOI: 10.1364/OE.18.013964

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  14 in total

1.  Space-division multiplexing optical coherence tomography.

Authors:  Chao Zhou; Aneesh Alex; Janarthanan Rasakanthan; Yutao Ma
Journal:  Opt Express       Date:  2013-08-12       Impact factor: 3.894

2.  High resolution in vivo imaging of the lamina cribrosa.

Authors:  Sung C Park; Robert Ritch
Journal:  Saudi J Ophthalmol       Date:  2011-05-08

3.  Silicon photonic integrated circuit swept-source optical coherence tomography receiver with dual polarization, dual balanced, in-phase and quadrature detection.

Authors:  Zhao Wang; Hsiang-Chieh Lee; Diedrik Vermeulen; Long Chen; Torben Nielsen; Seo Yeon Park; Allan Ghaemi; Eric Swanson; Chris Doerr; James Fujimoto
Journal:  Biomed Opt Express       Date:  2015-06-17       Impact factor: 3.732

4.  Estimation of Jones matrix, birefringence and entropy using Cloude-Pottier decomposition in polarization-sensitive optical coherence tomography.

Authors:  Masahiro Yamanari; Satoru Tsuda; Taiki Kokubun; Yukihiro Shiga; Kazuko Omodaka; Naoko Aizawa; Yu Yokoyama; Noriko Himori; Shiho Kunimatsu-Sanuki; Kazuichi Maruyama; Hiroshi Kunikata; Toru Nakazawa
Journal:  Biomed Opt Express       Date:  2016-08-19       Impact factor: 3.732

5.  Pixel-wise segmentation of severely pathologic retinal pigment epithelium and choroidal stroma using multi-contrast Jones matrix optical coherence tomography.

Authors:  Shinnosuke Azuma; Shuichi Makita; Arata Miyazawa; Yasushi Ikuno; Masahiro Miura; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2018-06-06       Impact factor: 3.732

6.  Scleral birefringence as measured by polarization-sensitive optical coherence tomography and ocular biometric parameters of human eyes in vivo.

Authors:  Masahiro Yamanari; Satoko Nagase; Shinichi Fukuda; Kotaro Ishii; Ryosuke Tanaka; Takeshi Yasui; Tetsuro Oshika; Masahiro Miura; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2014-04-03       Impact factor: 3.732

7.  Evaluating glaucoma damage: emerging imaging technologies.

Authors:  Tigran Kostanyan; Gadi Wollstein; Joel S Schuman
Journal:  Expert Rev Ophthalmol       Date:  2015-02-09

Review 8.  New developments in optical coherence tomography.

Authors:  Tigran Kostanyan; Gadi Wollstein; Joel S Schuman
Journal:  Curr Opin Ophthalmol       Date:  2015-03       Impact factor: 3.761

9.  Noise-immune complex correlation for optical coherence angiography based on standard and Jones matrix optical coherence tomography.

Authors:  Shuichi Makita; Kazuhiro Kurokawa; Young-Joo Hong; Masahiro Miura; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2016-03-29       Impact factor: 3.732

10.  Optical rheology of porcine sclera by birefringence imaging.

Authors:  Masahiro Yamanari; Kotaro Ishii; Shinichi Fukuda; Yiheng Lim; Lian Duan; Shuichi Makita; Masahiro Miura; Tetsuro Oshika; Yoshiaki Yasuno
Journal:  PLoS One       Date:  2012-09-06       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.