Arzu Ari1, Hasan Areabi, James B Fink. 1. Division of Respiratory Therapy, School of Health Professions, Georgia State University, PO Box 4019, Atlanta GA 30302-4019, USA. aari1@gsu.edu
Abstract
BACKGROUND: The position of the jet or ultrasonic nebulizer in the ventilator circuit impacts drug delivery during mechanical ventilation, but has not been extensively explored, and no study has examined all of the commonly used nebulizers. METHODS: Drug delivery from jet, vibrating-mesh, and ultrasonic nebulizers and pressurized metered-dose inhaler (pMDI) with spacer was compared in a model of adult mechanical ventilation, with heated/humidified and non-humidified ventilator circuits. Albuterol sulfate was aerosolized at 3 circuit positions: (1) between the endotracheal tube and the Y-piece; (2) 15 cm from Y-piece; and (3) 15 cm from the ventilator, with each device (n = 3) using adult settings (tidal volume 500 mL, ramp flow pattern, 15 breaths/min, peak inspiratory flow 60 L/min, and PEEP 5 cm H(2)O). The drug deposited on an absolute filter distal to an 8.0-mm inner-diameter endotracheal tube was eluted and analyzed via spectrophotometry (276 nm), and is reported as mean +/- SD percent of total nominal or emitted dose. RESULTS: The vibrating-mesh nebulizer, ultrasonic nebulizer, and pMDI with spacer were most efficient in position 2 with both non-humidified (30.2 +/- 1.0%, 24.7 +/- 4.4%, and 27.8 +/- 3.3%, respectively) and heated/humidified circuits (16.8 +/- 2.6%, 16.5 +/- 4.3%, and 17 +/- 1.0%, respectively). In contrast, the jet nebulizer was most efficient in position 3 under both non-humidified (14.7 +/- 1.5%) and heated/humidified (6.0 +/- 0.1%) conditions. In positions 2 and 3, all devices delivered approximately 2-fold more drug under non-humidified than under heated/humidified conditions (P < .01). At position 1 only the pMDI delivered substantially more drug than with the non-humidified circuit. CONCLUSION: During mechanical ventilation the optimal drug delivery efficiency depends on the aerosol generator, the ventilator circuit, and the aerosol generator position.
BACKGROUND: The position of the jet or ultrasonic nebulizer in the ventilator circuit impacts drug delivery during mechanical ventilation, but has not been extensively explored, and no study has examined all of the commonly used nebulizers. METHODS: Drug delivery from jet, vibrating-mesh, and ultrasonic nebulizers and pressurized metered-dose inhaler (pMDI) with spacer was compared in a model of adult mechanical ventilation, with heated/humidified and non-humidified ventilator circuits. Albuterol sulfate was aerosolized at 3 circuit positions: (1) between the endotracheal tube and the Y-piece; (2) 15 cm from Y-piece; and (3) 15 cm from the ventilator, with each device (n = 3) using adult settings (tidal volume 500 mL, ramp flow pattern, 15 breaths/min, peak inspiratory flow 60 L/min, and PEEP 5 cm H(2)O). The drug deposited on an absolute filter distal to an 8.0-mm inner-diameter endotracheal tube was eluted and analyzed via spectrophotometry (276 nm), and is reported as mean +/- SD percent of total nominal or emitted dose. RESULTS: The vibrating-mesh nebulizer, ultrasonic nebulizer, and pMDI with spacer were most efficient in position 2 with both non-humidified (30.2 +/- 1.0%, 24.7 +/- 4.4%, and 27.8 +/- 3.3%, respectively) and heated/humidified circuits (16.8 +/- 2.6%, 16.5 +/- 4.3%, and 17 +/- 1.0%, respectively). In contrast, the jet nebulizer was most efficient in position 3 under both non-humidified (14.7 +/- 1.5%) and heated/humidified (6.0 +/- 0.1%) conditions. In positions 2 and 3, all devices delivered approximately 2-fold more drug under non-humidified than under heated/humidified conditions (P < .01). At position 1 only the pMDI delivered substantially more drug than with the non-humidified circuit. CONCLUSION: During mechanical ventilation the optimal drug delivery efficiency depends on the aerosol generator, the ventilator circuit, and the aerosol generator position.
Authors: Robert M DiBlasi; Dave N Crotwell; Shuijie Shen; Jiang Zheng; James B Fink; Delphine Yung Journal: Pulm Circ Date: 2016-03 Impact factor: 3.017
Authors: Wei-Ren Ke; Rachel Yoon Kyung Chang; Philip Chi Lip Kwok; Patricia Tang; Lan Chen; Donghao Chen; Hak-Kim Chan Journal: Ann Transl Med Date: 2021-04
Authors: Donna K Parker; Shuijie Shen; Jiang Zheng; D Dunbar Ivy; Dave N Crotwell; Justin C Hotz; Robert M DiBlasi Journal: Pediatr Crit Care Med Date: 2017-06 Impact factor: 3.624
Authors: Zoe E Athanassa; Sophia L Markantonis; Marina-Zoe F Fousteri; Pavlos M Myrianthefs; Eleni G Boutzouka; Athanassios Tsakris; George J Baltopoulos Journal: Intensive Care Med Date: 2012-07-19 Impact factor: 17.440
Authors: Garyphallia Poulakou; Dimitrios K Matthaiou; David P Nicolau; Georgios Siakallis; George Dimopoulos Journal: Drugs Date: 2017-09 Impact factor: 9.546
Authors: Markus Hilpert; Vesna Ilievski; Shao-Yiu Hsu; Ana M Rule; Pablo Olmedo; German Drazer Journal: J Colloid Interface Sci Date: 2020-10-12 Impact factor: 8.128