Literature DB >> 2058496

MR imaging of intracerebral blood: diversity in the temporal pattern at 0.5 and 1.0 T.

A Zyed1, L A Hayman, R N Bryan.   

Abstract

MR scans were obtained at 0.5 and 1.0 T in 40 patients with 46 intracerebral hematomas categorized as hyperacute (0-2 days), acute (3-7 days), subacute (8-14 days), and chronic (15 days to 6 years). In a retrospective review, the signal intensity of the lesions was compared with that of normal white matter of the brain on spin-density, T1-, and T2-weighted spin-echo and T1-weighted gradient-echo sequences. The classic appearance and evolution of hematomas described in the literature at 1.5 T were not found in a significant number of the cases reviewed. In the hyperacute group, only five of eight hematomas had signal intensities that were hypointense relative to brain on T2-weighted images. Two of eight hyperacute hematomas were hyperintense relative to brain on the T1-weighted spin-echo images. However, T1-weighted gradient-echo images reliably demonstrated a hypointense signal in some portion of the hematoma in 45 of 46 cases. We conclude that while there is no constant temporal pattern on spin-echo or gradient-echo sequences, there are signal-intensity changes suggestive of hemorrhage in nearly all hematomas imaged at 0.5 and 1.0 T. Although the inconsistency may be frustrating from a diagnostic standpoint, this variability may reveal important individual differences in hematomas and the brain that surrounds them, and thus be clinically significant. Before these data can be mechanistically analyzed, the reason for contrast on MR scans of hematoma must be better understood.

Entities:  

Mesh:

Year:  1991        PMID: 2058496      PMCID: PMC8332990     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  5 in total

Review 1.  Intracranial hemorrhage: the role of magnetic resonance imaging.

Authors:  Peter D Schellinger; Jochen B Fiebach
Journal:  Neurocrit Care       Date:  2004       Impact factor: 3.210

2.  Contrast of artificial subcutaneous hematomas in MRI over time.

Authors:  Eva Maria Hassler; Kathrin Ogris; Andreas Petrovic; Bernhard Neumayer; Thomas Widek; Kathrin Yen; Eva Scheurer
Journal:  Int J Legal Med       Date:  2014-11-23       Impact factor: 2.686

3.  Is haemosiderin visible indefinitely on gradient-echo MRI following traumatic intracerebral haemorrhage?

Authors:  A Messori; G Polonara; C Mabiglia; U Salvolini
Journal:  Neuroradiology       Date:  2003-10-25       Impact factor: 2.804

4.  The safety and effectiveness of low field intraoperative MRI guidance in frameless stereotactic biopsies of brain tumours-design and interim analysis of a prospective randomized trial.

Authors:  M Czyż; P Tabakow; A Weiser; B E Lechowicz-Głogowska; L W Zub; W Jarmundowicz
Journal:  Neurosurg Rev       Date:  2013-07-03       Impact factor: 3.042

5.  Detection and volume estimation of artificial hematomas in the subcutaneous fatty tissue: comparison of different MR sequences at 3.0 T.

Authors:  Kathrin Ogris; Andreas Petrovic; Sylvia Scheicher; Hanna Sprenger; Martin Urschler; Eva Maria Hassler; Kathrin Yen; Eva Scheurer
Journal:  Forensic Sci Med Pathol       Date:  2017-03-01       Impact factor: 2.007

  5 in total