Ventilation inhomogeneity is one criterion among many in multidimensional PEEP titration.

Zhanqi Zhao, Daniel Steinmann, Inéz Frerichs, Josef Guttmann, Knut Möller.   

Abstract

Entities:  

Mesh:

Year:  2010        PMID: 20584342      PMCID: PMC2911739          DOI: 10.1186/cc9037

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


× No keyword cloud information.

We appreciate the commentary from Dr Costa and Dr Amato [1] on our recent study [2], in which we proposed that ventilation inhomogeneity should be regarded as an additional prospective index along with blood gases, lung mechanics and hemodynamics in a multifactorial method to optimize positive end-expiratory pressure (PEEP) at the bedside. We agree with Costa and Amato that some ventilation heterogeneity may be good [1]. Especially in patients with normal lungs, inhomogeneity of lung perfusion and ventilation along the gravity axis match each other - a match that is essential to optimize gas exchange. Little attention was paid, however, to isogravitational inhomogeneity of pulmonary perfusion and ventilation. When isogravitational inhomogeneity is included in the estimation, the influence of gravity is no longer dominant [3,4]. Minimizing the ventilation inhomogeneity during PEEP titration is not intended to eliminate inhomogeneity at all (which is impossible by PEEP alone), but rather to find a balance between overdistension and atelectasis. Physiological hetero geneity (good heterogeneity) may be preserved at the selected PEEP level. The global inhomogeneity index [2] can be independently combined with any region-of-interest-definition method, if appropriate. Given that no perfect method exists currently for identification of collapsed lung areas by electrical impedance tomography, our approach [5] guarantees to include as much of the collapsed lung regions as is detectable in the analysis of ventilation inhomogeneity and provides satisfactory results, as shown in a preliminary study by comparison with computed tomography. The titration of PEEP actually requires a multidimensional approach. A single ideal PEEP level, satisfying all clinical objectives and situations, may even not exist. A weighted combination of lung mechanics, blood gas analysis and imaging techniques to titrate PEEP therefore seems appealing and promising.

Abbreviations

PEEP: positive end-expiratory pressure.

Competing interests

The authors declare that they have no competing interests.
  4 in total

1.  A lung area estimation method for analysis of ventilation inhomogeneity based on electrical impedance tomography.

Authors:  Zhanqi Zhao; Daniel Steinmann; Danijela Müller-Zivkovic; Jörg Martin; Inéz Frerichs; Josef Guttmann; Knut Möller
Journal:  J Xray Sci Technol       Date:  2010       Impact factor: 1.535

2.  Counterpoint: Gravity is not the major factor determining the distribution of blood flow in the healthy human lung.

Authors:  Robb Glenny
Journal:  J Appl Physiol (1985)       Date:  2008-05

3.  Can heterogeneity in ventilation be good?

Authors:  Eduardo L V Costa; Marcelo B P Amato
Journal:  Crit Care       Date:  2010-03-22       Impact factor: 9.097

4.  PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography.

Authors:  Zhanqi Zhao; Daniel Steinmann; Inéz Frerichs; Josef Guttmann; Knut Möller
Journal:  Crit Care       Date:  2010-01-30       Impact factor: 9.097

  4 in total
  2 in total

1.  The global inhomogeneity index assessed by electrical impedance tomography overestimates PEEP requirement in patients with ARDS: an observational study.

Authors:  Serge J H Heines; Sebastiaan A M de Jongh; Ulrich Strauch; Iwan C C van der Horst; Marcel C G van de Poll; Dennis C J J Bergmans
Journal:  BMC Anesthesiol       Date:  2022-08-15       Impact factor: 2.376

2.  Effect of tidal volume and positive end-expiratory pressure on expiratory time constants in experimental lung injury.

Authors:  William R Henderson; Paolo B Dominelli; Yannick Molgat-Seon; Rachel Lipson; Donald E G Griesdale; Mypinder Sekhon; Najib Ayas; A William Sheel
Journal:  Physiol Rep       Date:  2016-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.