Literature DB >> 20584032

Reliability of the Respiratory Movement Measuring Instrument, RMMI.

Monika Fagevik Olsén1,2, Karin Romberg2.   

Abstract

INTRODUCTION: A new instrument to measure breathing movements, Respiratory Movement Measuring Instrument (RMMI), has been developed. There is still a lack of knowledge about the reliability of the instrument.
OBJECTIVES: The aim was to investigate reliability of the RMMI.
METHODS: In this trial, RMMI (ReMo Inc. Keldnaholt, Reykjavik, Iceland) was used. Inter- and intrarater reliability was performed on 30 volunteers who were tested three times in the supine position. Two of the tests were performed by one of the authors and the third test by the other. Intrasubject reliability was tested on 10 volunteers 12 times randomly during 1 h. Intra-instrument reliability was performed by measuring 12 solid surfaces where the instrument was placed horizontally against a couch or vertically against a chair.
RESULTS: Intra-rater reliability: The correlations were moderate to strong (r = 0.54-0.94) except for the left lower thoracic position r = 0.35. Inter-rater reliability: The correlations were strong (r = 0.71-0.99) except for the left lower thoracic position r = 0.35. The strongest correlations were seen on the tests on abdominal breathing movements. Intra subject reliability: The over-all difference within and between the participants and test was non-significant (P = 0.98). The average difference between the tests was 1.4 mm. Intra instrument: The differences between the measurements were small (mean 0.15 mm). The over-all difference was non-significant (P = 0.79).
CONCLUSION: The RMMI is a reliable instrument and usable in both clinical practice and research.

Entities:  

Mesh:

Year:  2010        PMID: 20584032     DOI: 10.1111/j.1475-097X.2010.00951.x

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  5 in total

1.  Reliability and preliminary reference values for the Total Faulty Breathing Scale (TFBS): A cross-sectional study.

Authors:  Vikram Mohan; Jonathan Branney; Carol Clark; Rebecca Neal; Madhanagopal Jagannathan; Aatit Paungmali; Maria Perri
Journal:  Health Sci Rep       Date:  2022-05-24

2.  Recovery after stabilising surgery for 'flail chest'.

Authors:  M Fagevik Olsén; D Pazooki; H Granhed
Journal:  Eur J Trauma Emerg Surg       Date:  2013-04-30       Impact factor: 3.693

3.  Physical function and pain after surgical or conservative management of multiple rib fractures - a follow-up study.

Authors:  Monika Fagevik Olsén; Margareta Slobo; Lena Klarin; Eva-Corina Caragounis; David Pazooki; Hans Granhed
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-10-28       Impact factor: 2.953

4.  The best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor.

Authors:  Haijuan Liu; Shaopeng Guo; Huilin Liu; Hao Zhang; Sujie Chen; Tsugumi Kuramoto-Ahuja; Tamae Sato; Junichiro Kaneko; Ko Onoda; Hitoshi Maruyama
Journal:  J Phys Ther Sci       Date:  2018-04-20

5.  Temperature thresholds and screening of febrile people by non-contact measurement of the face using infrared thermography - A methodology proposal.

Authors:  Pablo Rodrigues Muniz; Josemar Simão; Reginaldo Barbosa Nunes; Hércules Lázaro Morais Campos; Natália Queirós Santos; Andriele Ninke; João Thomaz Lemos
Journal:  Sens Biosensing Res       Date:  2022-08-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.