Literature DB >> 20583390

The first fifty consecutive Bentall operations with a prefabricated tissue-valved aortic conduit: a single-center experience.

Hassina Baraki1, Ammar Al Ahmad, Samir Sarikouch, Nurbol Koigeldiev, Nawid Khaladj, Christian Hagl, Maximillian Pichlmaier, Axel Haverich, Malakh Shrestha.   

Abstract

BACKGROUND AND AIM OF THE STUDY: Composite replacement is the standard treatment for the repair of aortic aneurysm with aortic valve pathology. With improved long-term durability and no requirement for long-term anticoagulation, tissue-valved conduits have become increasingly popular. Herein are reported the results achieved with 50 consecutive 'Bentall' operations, using the first commercially available prefabricated stentless tissue-valved conduit (Vascutek BioValsalva).
METHODS: Between September 2007 and September 2009, a total of 50 patients (10 females, 40 males; mean age 65 +/- 7 years) received a BioValsalva conduit. Concomitant procedures included coronary artery bypass grafting (CABG; n = 15), other valve (n = 5), and aortic arch replacement with circulatory arrest (n = 20; three of these had an additional frozen elephant trunk). Four of the procedures were re-operations. A six-month follow up with echocardiography and clinical examination was completed in 25 patients.
RESULTS: The 30-day mortality was 8% (4/50). Three of these patients underwent concomitant procedures. The cardiopulmonary bypass (CPB) and cross-clamp times were 178 +/- 30 min and 106 +/- 7 min, respectively. The triple-layered vascular graft proved to be hemostatic, without suture-line bleeding. Both, the initial and follow up echocardiography showed no valvular insufficiency, with a mean gradient of 13 +/- 5 mmHg. All patients were in NYHA class I-II.
CONCLUSION: The BioValsalva prefabricated tissue-valved conduit showed very good early results. The ischemic time required to construct a 'home-made' stentless tissue-valved conduit was eliminated, thus reducing the cross-clamp time. The conduit also offered the hemodynamic advantages of a stentless valve.

Entities:  

Mesh:

Year:  2010        PMID: 20583390

Source DB:  PubMed          Journal:  J Heart Valve Dis        ISSN: 0966-8519


  2 in total

1.  Hemostatic modifications of the Bentall procedure: imbricated proximal suture and fibrin sealant reduce postoperative morbidity and mortality rates.

Authors:  Alessandro Della Corte; Francesco Baldascino; Francesca La Marca; Michelangelo Scardone; Gianantonio Nappi; Mariano Cefarelli; Luca S De Santo; Paolo Pepino; Maurizio Cotrufo; Marisa De Feo
Journal:  Tex Heart Inst J       Date:  2012

2.  Comparison of mid-term haemodynamic performance between the BioValsalva and the BioIntegral valved conduits after aortic root replacement.

Authors:  Daniel Wendt; Ayman Raweh; Stephan Knipp; Mohammed El Gabry; Mareike Eißmann; Daniel Sebastian Dohle; Konstantinos Tsagakis; Matthias Thielmann; Heinz Jakob; Jaroslav Benedik
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-04-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.