Literature DB >> 20582395

[Automated delivery of codes for charge in radiotherapy].

Michael Sauer1, Steffen Volz, Markus Hall, Fred Röhner, Hermann Frommhold, Anca-Ligia Grosu, Felix Heinemann.   

Abstract

BACKGROUND AND
PURPOSE: For the medical billing of Radiotherapy every fraction has to be encoded, including date and time of all administered treatments. With fractions averaging 30 per patient and about 2,500 new patients every year the number of Radiotherapy codes reaches an amount of 70,000 and more. Therefore, an automated proceeding for transferring and processing therapy codes has been developed at the Department of Radiotherapy Freiburg, Germany. This is a joint project of the Department of Radiotherapy, the Administration Department, and the Central IT Department of the University Hospital of Freiburg.
MATERIAL AND METHODS: The project consists of several modules whose collaboration makes the projected automated transfer of treatment codes possible. The first step is to extract the data from the department's Clinical Information System (MOSAIQ). These data are transmitted to the Central IT Department via an HL7 interface, where a check for corresponding hospitalization data is performed. In the further processing of the data, a matching table plays an important role allowing the transformation of a treatment code into a valid medical billing code. In a last step, the data are transferred to the medical billing system. RESULTS AND
CONCLUSION: After assembling and implementing the particular modules successfully, a first beta test was launched. In order to test the modules separately as well as the interaction of the components, extensive tests were performed during March 2006. Soon it became clear that the tested procedure worked efficiently and accurately. In April 2006, a pilot project with a few qualities of treatment (e.g., computed tomography, simulation) was put into practice. Since October 2006, nearly all Radiation Therapy codes (approximately 75,000) are being transferred to the comprehensive Hospital Information System (HIS) automatically in a daily routine.

Entities:  

Mesh:

Year:  2010        PMID: 20582395     DOI: 10.1007/s00066-010-2087-4

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  19 in total

Review 1.  Networks in the radiology department and the hospital.

Authors:  E Pelikan; E Kotter; U Timmermann
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

2.  Development of an HL7 interface engine, based on tree structure and streaming algorithm, for large-size messages which include image data.

Authors:  Ki Sung Um; Yun Sik Kwak; Hune Cho; Il Kon Kim
Journal:  Comput Methods Programs Biomed       Date:  2005-09-21       Impact factor: 5.428

3.  [HL7 standard--features, principles, and methodology].

Authors:  Miroslav Koncar
Journal:  Acta Med Croatica       Date:  2005

4.  [In GOA settlement do not omit: additions, case fees, expenses...].

Authors:  Anke Thomas
Journal:  MMW Fortschr Med       Date:  2007-06-07

5.  [Department and patient management in radiotherapy. The Freiburg model].

Authors:  Felix Heinemann; Fred Röhner; Marianne Schmucker; Gregor Bruggmoser; Karl Henne; Anca-Ligia Grosu; Hermann Frommhold
Journal:  Strahlenther Onkol       Date:  2009-03-28       Impact factor: 3.621

6.  Implementing HL7: from the standard's specification to production application.

Authors:  G Schadow; U Föhring; T Tolxdorff
Journal:  Methods Inf Med       Date:  1998-01       Impact factor: 2.176

7.  Helical tomotherapy as a new treatment technique for whole abdominal irradiation.

Authors:  Nathalie Rochet; Florian Sterzing; Alexandra Jensen; Julien Dinkel; Klaus Herfarth; Kai Schubert; Michael Eichbaum; Andreas Schneeweiss; Christof Sohn; Juergen Debus; Wolfgang Harms
Journal:  Strahlenther Onkol       Date:  2008-03       Impact factor: 3.621

8.  The minimum basic data set as the core of the Freiburg University Hospital information system.

Authors:  R Klar; A Zaiss; M Binder; I Schrögendorfer
Journal:  Medinfo       Date:  1995

9.  Helical tomotherapy. Experiences of the first 150 patients in Heidelberg.

Authors:  Florian Sterzing; Kai Schubert; Gabriele Sroka-Perez; Jörn Kalz; Jürgen Debus; Klaus Herfarth
Journal:  Strahlenther Onkol       Date:  2008-01       Impact factor: 3.621

10.  Improving dose homogeneity in large breasts by IMRT: efficacy and dosimetric accuracy of different techniques.

Authors:  Yasser Abo-Madyan; Martin Polednik; Angelika Rahn; Frank Schneider; Barbara Dobler; Frederik Wenz; Frank Lohr
Journal:  Strahlenther Onkol       Date:  2008-02       Impact factor: 3.621

View more
  2 in total

Review 1.  Quality control of involved-field radiotherapy for patients with early stage Hodgkin's lymphoma based on a central prospective review. Comparison of the results between two study generations of the German Hodgkin Study Group.

Authors:  J Kriz; C Bangard; U Haverkamp; R Bongartz; C Baues; A Engert; R-P Mueller; H T Eich
Journal:  Strahlenther Onkol       Date:  2012-06-14       Impact factor: 3.621

2.  [Survey of potential improvements during the course of the radiotherapy treatment--a patient questionnaire].

Authors:  Felix Momm; David Jooss; Carola J Xander; Sonja Adebahr; Viola Duncker-Rohr; Felix Heinemann; Simon Kirste; Marc-Benjamin Messmer; Anca-Ligia Grosu; Gerhild Becker
Journal:  Strahlenther Onkol       Date:  2011-10-28       Impact factor: 3.621

  2 in total