Literature DB >> 20579521

The Stayhealthy bioelectrical impedance analyzer predicts body fat in children and adults.

David N Erceg1, Christina M Dieli-Conwright, Amerigo E Rossuello, Nicole E Jensky, Stephanie Sun, E Todd Schroeder.   

Abstract

Bioelectrical impedance analysis (BIA) is a time-efficient and cost-effective method for estimating body composition. We hypothesized that there would be no significant difference between the Stayhealthy BC1 BIA and the selected reference methods when determining body composition. Thus, the purpose of the present study was to determine the validity of estimating percent body fat (%BF) using the Stayhealthy BIA with its most recently updated algorithms compared to the reference methods of dual-energy x-ray absorptiometry for adults and hydrostatic weighing for children. We measured %BF in 245 adults aged 18 to 80 years and 115 children aged 10 to 17 years. Body fat by BIA was determined using a single 50 kHz frequency handheld impedance device and proprietary software. Agreement between BIA and reference methods was assessed by Bland and Altman plots. Bland and Altman analysis for men, women, and children revealed good agreement between the reference methods and BIA. There was no significant difference by t tests between mean %BF by BIA for men, women, or children when compared to the respective reference method. Significant correlation values between BIA, and reference methods for all men, women, and children were 0.85, 0.88, and 0.79, respectively. Reliability (test-retest) was assessed by intraclass correlation coefficient and coefficient of variation. Intraclass correlation coefficient values were greater than 0.99 (P < .001) for men, women, and children with coefficient of variation values 3.3%, 1.8%, and 1.7%, respectively. The Stayhealthy BIA device demonstrated good agreement between reference methods using Bland and Altman analyses. Copyright 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20579521     DOI: 10.1016/j.nutres.2010.04.009

Source DB:  PubMed          Journal:  Nutr Res        ISSN: 0271-5317            Impact factor:   3.315


  8 in total

Review 1.  Body composition during growth in children: limitations and perspectives of bioelectrical impedance analysis.

Authors:  U G Kyle; C P Earthman; C Pichard; J A Coss-Bu
Journal:  Eur J Clin Nutr       Date:  2015-06-03       Impact factor: 4.016

2.  Injury initiates unfavourable weight gain and obesity markers in youth.

Authors:  Gregory D Myer; Avery D Faigenbaum; Kim Barber Foss; Yingying Xu; Jane Khoury; Lawrence M Dolan; Teri M McCambridge; Timothy E Hewett
Journal:  Br J Sports Med       Date:  2013-05-14       Impact factor: 13.800

3.  Diagnostic value of bioelectrical impedance analysis versus body mass index for detection of obesity among students.

Authors:  Seyed-Taghi Heydari; Seyed-Mohammad-Taghi Ayatollahi; Najaf Zare
Journal:  Asian J Sports Med       Date:  2011-06

4.  The Effect of a 12-Week Beta-hydroxy-beta-methylbutyrate (HMB) Supplementation on Highly-Trained Combat Sports Athletes: A Randomised, Double-Blind, Placebo-Controlled Crossover Study.

Authors:  Krzysztof Durkalec-Michalski; Jan Jeszka; Tomasz Podgórski
Journal:  Nutrients       Date:  2017-07-14       Impact factor: 5.717

5.  Relationship between the muscle relaxation effect and body muscle mass measured using bioelectrical impedance analysis: A nonrandomized controlled trial.

Authors:  Yoon-Ji Choi; Yun Hee Kim; Go Eun Bae; Joon Ho Yu; Seung Zhoo Yoon; Hee Won Kang; Kuen Su Lee; Jae-Hwan Kim; Yoon-Sook Lee
Journal:  J Int Med Res       Date:  2019-02-05       Impact factor: 1.671

6.  Evaluation of Body Fat Composition and Digit Ratio (2D:4D) in Polycystic Ovary Syndrome in Adolescents.

Authors:  Velusami Deepika; Perumal Preethy
Journal:  Curr Health Sci J       Date:  2021-09-30

7.  Percentage of body fat assessment using bioelectrical impedance analysis and dual-energy X-ray absorptiometry in a weight loss program for obese or overweight Chinese adults.

Authors:  Yi-Chun Li; Chia-Ing Li; Wen-Yuan Lin; Chiu-Shong Liu; Hua-Shui Hsu; Cheng-Chun Lee; Fei-Na Chen; Tsai-Chung Li; Cheng-Chieh Lin
Journal:  PLoS One       Date:  2013-04-01       Impact factor: 3.240

8.  Comparison of Standing Posture Bioelectrical Impedance Analysis with DXA for Body Composition in a Large, Healthy Chinese Population.

Authors:  Kuen-Tsann Chen; Yu-Yawn Chen; Chia-Wei Wang; Chih-Lin Chuang; Li-Ming Chiang; Chung-Liang Lai; Hsueh-Kuan Lu; Gregory B Dwyer; Shu-Ping Chao; Ming-Kuei Shih; Kuen-Chang Hsieh
Journal:  PLoS One       Date:  2016-07-28       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.