PURPOSE: To investigate the incremental diagnostic value of dual-bolus over single-contrast-bolus first pass magnetic resonance myocardial perfusion imaging (MR-MPI) for detection of significant coronary artery disease (CAD). MATERIALS AND METHODS: Patients (n = 49) with suspected CAD underwent first pass adenosine stress and rest MR-MPI and invasive coronary angiography (CA). Gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) was injected with a prebolus (1 mL) and a large bolus (0.1 mmol/kg). For the single-bolus technique, the arterial input function (AIF) was obtained from the large-contrast bolus. For the dual-bolus technique, the AIF was reconstructed from the prebolus. Absolute myocardial perfusion was calculated by Fermi-model constrained deconvolution. Receiver operating characteristic (ROC) analysis was used to investigate diagnostic accuracy of MR myocardial perfusion imaging for detection of significant CAD on CA at vessel-based analysis. RESULTS: The area under the curve (AUC) of the minimal stress perfusion value for the detection of significant CAD using the single-bolus and dual-bolus technique was 0.85 +/- 0.04 (95% confidence interval [CI], 0.77-0.93) and 0.77 +/- 0.05 (95% CI, 0.67-0.86), respectively. CONCLUSION: In this study the dual-bolus technique had no incremental diagnostic value over single-bolus technique for detection of significant CAD with the used contrast concentrations. (c) 2010 Wiley-Liss, Inc.
PURPOSE: To investigate the incremental diagnostic value of dual-bolus over single-contrast-bolus first pass magnetic resonance myocardial perfusion imaging (MR-MPI) for detection of significant coronary artery disease (CAD). MATERIALS AND METHODS:Patients (n = 49) with suspected CAD underwent first pass adenosine stress and rest MR-MPI and invasive coronary angiography (CA). Gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) was injected with a prebolus (1 mL) and a large bolus (0.1 mmol/kg). For the single-bolus technique, the arterial input function (AIF) was obtained from the large-contrast bolus. For the dual-bolus technique, the AIF was reconstructed from the prebolus. Absolute myocardial perfusion was calculated by Fermi-model constrained deconvolution. Receiver operating characteristic (ROC) analysis was used to investigate diagnostic accuracy of MR myocardial perfusion imaging for detection of significant CAD on CA at vessel-based analysis. RESULTS: The area under the curve (AUC) of the minimal stress perfusion value for the detection of significant CAD using the single-bolus and dual-bolus technique was 0.85 +/- 0.04 (95% confidence interval [CI], 0.77-0.93) and 0.77 +/- 0.05 (95% CI, 0.67-0.86), respectively. CONCLUSION: In this study the dual-bolus technique had no incremental diagnostic value over single-bolus technique for detection of significant CAD with the used contrast concentrations. (c) 2010 Wiley-Liss, Inc.
Authors: Neil Chatterjee; Brandon C Benefield; Kathleen R Harris; Jacob U Fluckiger; Timothy Carroll; Daniel C Lee Journal: Magn Reson Med Date: 2016-09-08 Impact factor: 4.668
Authors: Manish Motwani; Ananth Kidambi; Steven Sourbron; Timothy A Fairbairn; Akhlaque Uddin; Sebastian Kozerke; John P Greenwood; Sven Plein Journal: J Cardiovasc Magn Reson Date: 2014-02-24 Impact factor: 5.364
Authors: Federico E Mordini; Tariq Haddad; Li-Yueh Hsu; Peter Kellman; Tracy B Lowrey; Anthony H Aletras; W Patricia Bandettini; Andrew E Arai Journal: JACC Cardiovasc Imaging Date: 2014-01
Authors: Claudia Calcagno; Philip M Robson; Sarayu Ramachandran; Venkatesh Mani; Melanie Kotys-Traughber; Matthew Cham; Stefan E Fischer; Zahi A Fayad Journal: J Cardiovasc Magn Reson Date: 2013-05-24 Impact factor: 5.364
Authors: James R J Foley; Ananth Kidambi; John D Biglands; Neil Maredia; Catherine J Dickinson; Sven Plein; John P Greenwood Journal: J Cardiovasc Magn Reson Date: 2017-11-06 Impact factor: 5.364