Literature DB >> 20576016

The appropriateness and physician compliance of platelet usage by a computerized transfusion decision support system in a medical center.

Yi-Ching Lin1, Chao-Sung Chang, Chi-Jung Yeh, Yung-Chao Wu.   

Abstract

BACKGROUND: The prescribing of inappropriate platelet (PLT) transfusions is always a significant problem. A computerized transfusion decision support system (CTDSS) has been used in Kaohsiung Medical University Hospital since September 2004. In this study, the physician compliance and appropriateness of PLT usage after using the CTDSS were investigated. STUDY DESIGN AND METHODS: A total of 5887 PLT transfusion episodes between January and December 2008 were reviewed including the demographic data and the "true reason" for each transfusion practice. The pre- and posttransfusion PLT counts were retrieved. The physician compliance, the appropriateness of PLT usage, and the PLT increments after transfusion were investigated.
RESULTS: Physician compliance was 85.4%, and the appropriateness of PLT usage was 69.6%. The most commonly chosen indication from the CTDSS was "prophylactic use, PLT count ≤20×10(9) /L." The highest inappropriate order rate was from the emergency department. More than half of the inappropriate episodes were from the surgery unit. The inappropriate rates were significant in terms of both different order sources and functional units (p<0.0001). The posttransfusion PLT counts increased in two-thirds of the episodes, and most of them were with the pretransfusion PLT counts of less than 50×10(9) /L.
CONCLUSIONS: In Taiwan, the PLT concentration is too low-priced and this might cause the overuse of blood components. Under the global budget of National Health Insurance, preventing the overuse of blood components might serve as one of the mechanism to improve medical quality. The CTDSS should be more powerful and effective to intervene in the appropriateness of transfusion practice.
© 2010 American Association of Blood Banks.

Entities:  

Mesh:

Year:  2010        PMID: 20576016     DOI: 10.1111/j.1537-2995.2010.02757.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  4 in total

1.  Computerised decision support systems to promote appropriate use of blood products.

Authors:  Sheila A Fisher; Annemarie B Docherty; Carolyn Doree; Stephen P Hibbs; Michael F Murphy; Lise J Estcourt
Journal:  Cochrane Database Syst Rev       Date:  2017-02

2.  Choosing Wisely clinical decision support adherence and associated inpatient outcomes.

Authors:  Andrew M Heekin; John Kontor; Harry C Sax; Michelle S Keller; Anne Wellington; Scott Weingarten
Journal:  Am J Manag Care       Date:  2018-08       Impact factor: 2.229

3.  Health outcomes in recipients of blood transfusion - observational studies versus randomized clinical trials.

Authors:  Edward L Murphy
Journal:  ISBT Sci Ser       Date:  2013-06-01

Review 4.  A Systematic Review and Meta-Analysis of the Clinical Appropriateness of Blood Transfusion in China.

Authors:  Changtai Zhu; Yulu Gao; Zhiqiang Li; Qinyun Li; Zongshuai Gao; Yanqiu Liao; Zhifeng Deng
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.