Literature DB >> 20573528

An in vitro evaluation of apicoectomies and retropreparations using different methods.

Fábio Luiz Camargo Villela Berbert1, Norberto Batista de Faria-Júnior, Mário Tanomaru-Filho, Juliane Maria Guerreiro-Tanomaru, Idomeo Bonetti-Filho, Renato de Toledo Leonardo, Rosemary Adriana Chierici Marcantonio.   

Abstract

OBJECTIVES: The aim of this study was to evaluate: 1) the apical root surface, gutta-percha interface, and preparation time of root-end resections made with burs, ultrasound, or laser; and 2) the thickness of surrounding dentin after laser or ultrasonic root-end cavity preparation. STUDY
DESIGN: 1) Thirty root-filled teeth were resected as follows: Zekrya bur in group I, Chemical Vapor Deposition (CVD) ultrasonic tip (9.5107-8) in group II, and ErCr:YSGG (Waterlase) in group III. The preparation time was recorded. Replicas of the resected root-ends were examined under a scanning electron microscope (SEM). 2) Thirty root-filled teeth were submitted to apicectomies and root-end cavities were prepared by using: CVD (6.1107-6) ultrasonic retrotips (group IV), EMS (DT-060) ultrasonic retrotips (group V), and ErCr:YSGG laser tips (group VI). Replicas of the root apices were examined under a SEM.
RESULTS: There were no fissures or fractures on root-end surfaces. The bur produced the smoothest surface (P < .05). Group I had the lowest preparation time (P < .05). The best adaptation between the filling and the root canals walls was observed in group III, but it was not significantly different from group II (P < .05). No resected root-ends had cracks after preparation. Group VI showed the least minimum dentin thickness (P < .05).
CONCLUSIONS: The 3 methods evaluated did not cause any injury to the root-end surface, but they harmed the apical adaptation. Laser tips removed more dentin than ultrasonic retrotips and should be used with care to avoid overpreparation.
Copyright © 2010 Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20573528     DOI: 10.1016/j.tripleo.2010.03.004

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  3 in total

1.  Comparative evaluation of microleakage after root-end resection by erbium, chromium: Yttrium-scandium-gallium-garnet (Er, Cr:YSGG) laser and carbide bur with or without placement of mineral trioxide aggregate: An in vitro study.

Authors:  Shabnam Negi; Hari Das Adhikari; Dibyendu Mazumder; R Deirimika Lakiang; Sarita Bhardwaj
Journal:  J Conserv Dent       Date:  2019 Jul-Aug

2.  Behavior of human periodontal ligament cells on dentin surfaces ablated with an ultra-short pulsed laser.

Authors:  Jing Liu; Oleh Andrukhov; Markus Laky; Sylvia Nürnberger; Andreas Moritz; Peijun Lyu; Xiaohui Rausch-Fan
Journal:  Sci Rep       Date:  2017-10-06       Impact factor: 4.379

3.  Effect of Irrigating Agitation after Root End Preparation on the Wall Cleaning and Bond Strength of Calcium Silicate Material in Retrograde Obturation.

Authors:  Yahir Muñoz Valencia; Gislene Cristina Vertuan; Murilo Priori Alcalde; Rodrigo Ricci Vivan; Marcus Vinícius Reis Só; Marco Antonio Hungaro Duarte
Journal:  Eur J Dent       Date:  2021-07-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.