Literature DB >> 20572144

Real-time adaptive sequential design for optimal acquisition of arterial spin labeling MRI data.

Jingyi Xie1, Stuart Clare, Daniel Gallichan, Roger N Gunn, Peter Jezzard.   

Abstract

An optimal sampling schedule strategy based on the Fisher information matrix and the D-optimality criterion has previously been proposed as a formal framework for optimizing inversion time scheduling for multi-inversion-time arterial spin labeling experiments. Optimal sampling schedule possesses the primary advantage of improving parameter estimation precision but requires a priori estimation of plausible parameter distributions that may not be available in all situations. An adaptive sequential design approach addresses this issue by incorporating the optimal sampling schedule strategy into an adaptive process that iteratively updates the parameter estimates and adjusts the optimal sampling schedule accordingly as data are acquired. In this study, the adaptive sequential design method was experimentally implemented with a real-time feedback scheme on a clinical MRI scanner and was tested in six normal volunteers. Adapted schedules were found to accommodate the intrinsically prolonged arterial transit times in the occipital lobe of the brain. Simulation of applying the adaptive sequential design approach on subjects with pathologically reduced perfusion was also implemented. Simulation results show that the adaptive sequential design approach is capable of incorporating pathologic parameter information into an optimal arterial spin labeling scheduling design within a clinically useful experimental time. (c) 2010 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2010        PMID: 20572144     DOI: 10.1002/mrm.22398

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Real-time functional MRI using pseudo-continuous arterial spin labeling.

Authors:  Luis Hernandez-Garcia; Hesamoddin Jahanian; Mark K Greenwald; Jon-Kar Zubieta; Scott J Peltier
Journal:  Magn Reson Med       Date:  2011-03-28       Impact factor: 4.668

2.  Measurement of absolute arterial cerebral blood volume in human brain without using a contrast agent.

Authors:  Jun Hua; Qin Qin; James J Pekar; Peter C M van Zijl
Journal:  NMR Biomed       Date:  2011-05-24       Impact factor: 4.044

3.  Optimization and reliability of multiple postlabeling delay pseudo-continuous arterial spin labeling during rest and stimulus-induced functional task activation.

Authors:  Melvin Mezue; Andrew R Segerdahl; Thomas W Okell; Michael A Chappell; Michael E Kelly; Irene Tracey
Journal:  J Cereb Blood Flow Metab       Date:  2014-10-01       Impact factor: 6.200

4.  Optimizing experimental design for comparing models of brain function.

Authors:  Jean Daunizeau; Kerstin Preuschoff; Karl Friston; Klaas Stephan
Journal:  PLoS Comput Biol       Date:  2011-11-17       Impact factor: 4.475

5.  Investigating white matter perfusion using optimal sampling strategy arterial spin labeling at 7 Tesla.

Authors:  Alexander G Gardener; Peter Jezzard
Journal:  Magn Reson Med       Date:  2014-06-20       Impact factor: 4.668

  5 in total