Literature DB >> 20572107

Fetal cardiac scanning today.

Lindsey Allan1.   

Abstract

The ability to examine the structure of the fetal heart in real-time started over 30 years ago now. The field has seen very great advances since then, both in terms of technical improvements in ultrasound equipment and in dissemination of operator skills. A great deal has been learnt about normal cardiac function in the human fetus throughout gestation and how it is affected by pathologies of pregnancy. There is increasing recognition of abnormal heart structure during routine obstetric scanning, allowing referral for specialist diagnosis and counselling. It is now possible to make accurate diagnosis of cardiac malformations as early as 12 weeks of gestation. Early diagnosis of a major cardiac malformation in the fetus can provide the parents with a comprehensive prognosis, enabling them to make the most informed choice about the management of the pregnancy. (c) 2010 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2010        PMID: 20572107     DOI: 10.1002/pd.2540

Source DB:  PubMed          Journal:  Prenat Diagn        ISSN: 0197-3851            Impact factor:   3.050


  6 in total

1.  MicroRNA biomarkers for early detection of embryonic malformations in pregnancy.

Authors:  Xuezheng Li; Zhiyong Zhao
Journal:  J Biomol Res Ther       Date:  2014-12

Review 2.  Highlights on MRI of the fetal body.

Authors:  Lucia Manganaro; Amanda Antonelli; Silvia Bernardo; Federica Capozza; Roberta Petrillo; Serena Satta; Valeria Vinci; Matteo Saldari; Francesca Maccioni; Laura Ballesio; Carlo Catalano
Journal:  Radiol Med       Date:  2017-11-21       Impact factor: 3.469

3.  Genetic counseling in the adult with congenital heart disease: what is the role?

Authors:  Luke Burchill; Steven Greenway; Candice K Silversides; Seema Mital
Journal:  Curr Cardiol Rep       Date:  2011-08       Impact factor: 2.931

4.  Routine use of color Doppler in fetal heart scanning in a low-risk population.

Authors:  Torbjørn Moe Eggebø; Claudia Heien; Magne Berget; Christian Lycke Ellingsen
Journal:  ISRN Obstet Gynecol       Date:  2012-05-20

5.  The use of EST expression matrixes for the quality control of gene expression data.

Authors:  Andrew T Milnthorpe; Mikhail Soloviev
Journal:  PLoS One       Date:  2012-03-08       Impact factor: 3.240

6.  The electrical heart axis of the fetus between 18 and 24 weeks of gestation: A cohort study.

Authors:  Carlijn Lempersz; Lore Noben; Sally-Ann B Clur; Edwin van den Heuvel; Zhouzhao Zhan; Monique Haak; S Guid Oei; Rik Vullings; Judith O E H van Laar
Journal:  PLoS One       Date:  2021-12-16       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.