Estimate of the attenuation coefficient using a clinical array transducer for the detection of cervical ripening in human pregnancy.

Yassin Labyed1, Timothy A Bigelow, Barbara L McFarlin.   

Abstract

Premature delivery is the leading cause of infant mortality in the United States. Currently, premature delivery cannot be prevented and new treatments are difficult to develop due to the inability to diagnose symptoms prior to uterine contractions. Cervical ripening is a long period that precedes the active phase of uterine contractions and cervical dilation. The changes in the microstructure of the cervix during cervical ripening suggest that the ultrasonic attenuation should decrease. The objective of this study is to use the reference phantom algorithm to estimate the ultrasonic attenuation in the cervix of pregnant human patients. Prior to applying the algorithm to in vivo human data, two homogeneous phantoms with known attenuation coefficients were used to validate the algorithm and to find the length and the width of the region of interest (ROI) that achieves the smallest error in the attenuation coefficient estimates. In the phantom data, we found that the errors in the attenuation coefficients estimates are less than 12% for ROIs that contain 40 wavelengths or more axially and 30 echo lines or more laterally. The reference phantom algorithm was then used to obtain attenuation maps of the echoes from two human pregnant cervices at different gestational ages. It was observed that the mean of the attenuation coefficient estimates in the cervix of the patient at a more advanced gestational age is smaller than the mean of the attenuation coefficient estimates in the cervix of the patient at an earlier gestational age which suggests that ultrasonic attenuation decreases with increasing gestational age. We also observed a large variance between the attenuation coefficient estimates in the different regions of the cervix due to the natural variation in tissue micro-structures across the cervix. The preliminary results indicate that the algorithm could potentially provide an important diagnostic tool for diagnosing the risk of premature delivery.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20570308      PMCID: PMC2956845          DOI: 10.1016/j.ultras.2010.05.005

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  19 in total

1.  Further evidence of a decorin-collagen interaction in the disruption of cervical collagen fibers during rat gestation.

Authors:  P C Leppert; R Kokenyesi; C A Klemenich; J Fisher
Journal:  Am J Obstet Gynecol       Date:  2000-04       Impact factor: 8.661

2.  Scatterer size estimation in pulse-echo ultrasound using focused sources: calibration measurements and phantom experiments.

Authors:  Timothy A Bigelow; William D O'Brien
Journal:  J Acoust Soc Am       Date:  2004-07       Impact factor: 1.840

3.  Estimation of total attenuation and scatterer size from backscattered ultrasound waveforms.

Authors:  Timothy A Bigelow; Michael L Oelze; William D O'Brien
Journal:  J Acoust Soc Am       Date:  2005-03       Impact factor: 1.840

4.  Impact of local attenuation approximations when estimating correlation length from backscattered ultrasound echoes.

Authors:  Timothy A Bigelow; William D O'Brien
Journal:  J Acoust Soc Am       Date:  2006-07       Impact factor: 1.840

5.  Attenuation estimation using spectral cross-correlation.

Authors:  Hyungsuk Kim; Tomy Varghese
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-03       Impact factor: 2.725

6.  Attenuation estimations using envelope echo data: analysis and simulations.

Authors:  Haifeng Tu; James Zagzebski; Quan Chen
Journal:  Ultrasound Med Biol       Date:  2006-03       Impact factor: 2.998

7.  Ultrasound attenuation estimation using backscattered echoes from multiple sources.

Authors:  Timothy A Bigelow
Journal:  J Acoust Soc Am       Date:  2008-08       Impact factor: 1.840

8.  The contribution of preterm birth to infant mortality rates in the United States.

Authors:  William M Callaghan; Marian F MacDorman; Sonja A Rasmussen; Cheng Qin; Eve M Lackritz
Journal:  Pediatrics       Date:  2006-10       Impact factor: 7.124

Review 9.  Anatomy and physiology of cervical ripening.

Authors:  P C Leppert
Journal:  Clin Obstet Gynecol       Date:  1995-06       Impact factor: 2.190

10.  Spectral characterization and attenuation measurements in ultrasound.

Authors:  S W Flax; N J Pelc; G H Glover; F D Gutmann; M McLachlan
Journal:  Ultrason Imaging       Date:  1983-04       Impact factor: 1.578

View more
  22 in total

1.  Evaluation of the impact of backscatter intensity variations on ultrasound attenuation estimation.

Authors:  Eenas A Omari; Tomy Varghese; Ernest L Madsen; Gary Frank
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

2.  Development of an ultrasonic method to detect cervical remodeling in vivo in full-term pregnant women.

Authors:  Barbara L McFarlin; Jennifer Balash; Viksit Kumar; Timothy A Bigelow; Xavier Pombar; Jacques S Abramowicz; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2015-05-23       Impact factor: 2.998

Review 3.  The mechanical role of the cervix in pregnancy.

Authors:  Kristin M Myers; Helen Feltovich; Edoardo Mazza; Joy Vink; Michael Bajka; Ronald J Wapner; Timothy J Hall; Michael House
Journal:  J Biomech       Date:  2015-03-11       Impact factor: 2.712

4.  Cervical attenuation as a measure of preterm delivery: impact of different region of interest sizes.

Authors:  Viksit Kumar; Timothy Bigelow; Barbara McFarlin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

5.  Properties of phantom tissuelike polymethylpentene in the frequency range 20-70 MHZ.

Authors:  Ernest L Madsen; Meagan E Deaner; James Mehi
Journal:  Ultrasound Med Biol       Date:  2011-08       Impact factor: 2.998

6.  Repeatability and Reproducibility of a Clinically Based QUS Phantom Study and Methodologies.

Authors:  Aiguo Han; Michael P Andre; John W Erdman; Rohit Loomba; Claude B Sirlin; William D O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-07-09       Impact factor: 2.725

7.  Strain at the internal cervical os assessed with quasi-static elastography is associated with the risk of spontaneous preterm delivery at ≤34 weeks of gestation.

Authors:  Edgar Hernandez-Andrade; Maynor Garcia; Hyunyoung Ahn; Steven J Korzeniewski; Homam Saker; Lami Yeo; Tinnakorn Chaiworapongsa; Sonia S Hassan; Roberto Romero
Journal:  J Perinat Med       Date:  2015-11       Impact factor: 1.901

8.  Quantitative Ultrasound Biomarkers Based on Backscattered Acoustic Power: Potential for Quantifying Remodeling of the Human Cervix during Pregnancy.

Authors:  Quinton W Guerrero; Helen Feltovich; Ivan M Rosado-Mendez; Lindsey C Carlson; Timothy J Hallcor
Journal:  Ultrasound Med Biol       Date:  2018-11-22       Impact factor: 2.998

9.  Exvivo ultrasound attenuation coefficient for human cervical and uterine tissue from 5 to 10 MHz.

Authors:  Miklos Z Kiss; Tomy Varghese; M A Kliewer
Journal:  Ultrasonics       Date:  2010-11-27       Impact factor: 2.890

10.  Beyond Cervical Length: A Pilot Study of Ultrasonic Attenuation for Early Detection of Preterm Birth Risk.

Authors:  Barbara L McFarlin; Viksit Kumar; Timothy A Bigelow; Douglas G Simpson; Rosemary C White-Traut; Jacques S Abramowicz; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2015-08-08       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.