Literature DB >> 20569550

A double catheter technique for elongated middle cerebral artery bifurcation aneurysm. A case report.

S C Kwon1, Y S Shin, H S Kim, S Y Kim.   

Abstract

SUMMARY: We report a case of an elongated middle cerebral artery bifurcation aneurysm which was managed using an endovascular double catheter technique. After positioning two microcatheters, one at the distal dome and the other at the proximal dome, two coils were subsequently deployed through each microcatheter.We created a proximal supporting coil frame using one microcatheter and preserved the parent artery, and then deposited subsequent packing coils at the distal aneurysm sac region using the other microcatheter. The proximal framing coils did not detach prior to obtaining satisfactory aneurysm packing through the distally positioned microcatheter. This approach allowed for the proximal coil to be withdrawn if there was any evidence of the proximal coil frame changing shape or of parent artery protrusion. This double microcatheter technique provided safe and effective treatment of an elongated middle cerebral artery bifurcation aneurysm.

Entities:  

Year:  2006        PMID: 20569550      PMCID: PMC3355356          DOI: 10.1177/159101990601200108

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  5 in total

1.  Endovascular treatment of wide-necked aneurysms by using two microcatheters: techniques and outcomes in 25 patients.

Authors:  O-Ki Kwon; Seong Hyun Kim; Bae Ju Kwon; Hyun-Seung Kang; Jae Hyoung Kim; Chang Wan Oh; Moon Hee Han
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

2.  International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial.

Authors:  Andrew Molyneux; Richard Kerr; Irene Stratton; Peter Sandercock; Mike Clarke; Julia Shrimpton; Rury Holman
Journal:  Lancet       Date:  2002-10-26       Impact factor: 79.321

3.  Periprocedural morbidity and mortality associated with endovascular treatment of intracranial aneurysms.

Authors:  Hae-Kwan Park; Michael Horowitz; Charles Jungreis; Julie Genevro; Christopher Koebbe; Elad Levy; Amin Kassam
Journal:  AJNR Am J Neuroradiol       Date:  2005-03       Impact factor: 3.825

4.  The usefulness of the new "double-catheter technique" in the treatment of parent artery incorporated wide-necked aneurysm with guglielmi detachable coils. Technical notes.

Authors:  Y S Shin; D I Kim; S I Lee; J I Chung; P H Yoon; K C Lee
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

5.  Double microcatheter technique for detachable coil treatment of large, wide-necked intracranial aneurysms.

Authors:  B W Baxter; D Rosso; S P Lownie
Journal:  AJNR Am J Neuroradiol       Date:  1998 Jun-Jul       Impact factor: 3.825

  5 in total
  3 in total

1.  Embolisation of internal carotid artery aneurysm using the double microcatheter technique - a case report.

Authors:  Robert Juszkat; Katarzyna Stanisławska; Karolina Kopińska; Włodzimierz Liebert; Jakub Moskal
Journal:  Pol J Radiol       Date:  2015-04-13

2.  Current Treatment Strategies for Intracranial Aneurysms: An Overview.

Authors:  Junjie Zhao; Hao Lin; Richard Summers; Mingmin Yang; Brian G Cousins; Janice Tsui
Journal:  Angiology       Date:  2017-03-30       Impact factor: 3.619

3.  Endovascular treatment of a temporal bone pseudoaneurysm presenting as bloody otorrhea.

Authors:  Alexander G Bien; Marshall C Cress; Susan B Nguyen; Steven J Westgate; Ashish Nanda
Journal:  J Neurol Surg Rep       Date:  2013-07-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.