Literature DB >> 20567077

Diamond X-ray beam-position monitoring using signal readout at the synchrotron radiofrequency.

J Morse1, B Solar, H Graafsma.   

Abstract

Single-crystal diamond is a material with great potential for the fabrication of X-ray photon beam-position monitors with submicrometre spatial resolution. Low X-ray absorption combined with radiation hardness and excellent thermal-mechanical properties make possible beam-transmissive diamond devices for monitoring synchrotron and free-electron laser X-ray beams. Tests were made using a white bending-magnet synchrotron X-ray beam at DESY to investigate the performance of a position-sensitive diamond device using radiofrequency readout electronics. The device uniformity and position response were measured in a 25 microm collimated X-ray beam with an I-Tech Libera ;Brilliance' system. This readout system was designed for position measurement and feedback control of the electron beam in the synchrotron storage ring, but, as shown here, it can also be used for accurate position readout of a quadrant-electrode single-crystal diamond sensor. The centre-of-gravity position of the F4 X-ray beam at the DORIS III synchrotron was measured with the diamond signal output digitally sampled at a rate of 130 Msample s(-1) by the Brilliance system. Narrow-band filtering and digital averaging of the position signals resulted in a measured position noise below 50 nm (r.m.s.) for a 10 Hz bandwidth.

Entities:  

Year:  2010        PMID: 20567077     DOI: 10.1107/S0909049510016547

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  3 in total

1.  Transmission-mode diamond white-beam position monitor at NSLS.

Authors:  Erik M Muller; John Smedley; Jen Bohon; Xi Yang; Mengjia Gaowei; John Skinner; Gianluigi De Geronimo; Michael Sullivan; Marc Allaire; Jeffrey W Keister; Lonny Berman; Annie Héroux
Journal:  J Synchrotron Radiat       Date:  2012-03-17       Impact factor: 2.616

2.  A phase-space beam position monitor for synchrotron radiation.

Authors:  Nazanin Samadi; Bassey Bassey; Mercedes Martinson; George Belev; Les Dallin; Mark de Jong; Dean Chapman
Journal:  J Synchrotron Radiat       Date:  2015-06-25       Impact factor: 2.616

3.  Device for source position stabilization and beam parameter monitoring at inverse Compton X-ray sources.

Authors:  Benedikt Günther; Martin Dierolf; Klaus Achterhold; Franz Pfeiffer
Journal:  J Synchrotron Radiat       Date:  2019-08-07       Impact factor: 2.616

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.