Abstract

Accurate plantar pressure measurements are mandatory in both clinical and research contexts. Differences in accuracy, precision, reliability of pressure measurement devices (PMDs) prevented so far the onset of standardization processes and of reliable reference datasets. The Italian National Institute of Health (ISS) approved and conducted a scientific project aimed to design, validate and implement dedicated testing methods for both in-factory and on-the-field PMD assessment. A general-purpose experimental set-up was built, complete and suitable for the assessment of PMDs based on different sensor technology, electronic conditioning and mechanical solutions. Preliminary assessments have been conducted on 5 commercial PMDs. The study lead to the definition of: i) an appropriate set of instruments and procedures for PMD technical assessment; ii) a minimum set of significant parameters for the technical characterization of the PMD performance; iii) some recommendations to both manufacturers and end users for an appropriate use in clinics and in research context.

Mesh:

Year:  2010        PMID: 20567067     DOI: 10.4415/ANN_10_02_09

Source DB:  PubMed          Journal:  Ann Ist Super Sanita        ISSN: 0021-2571            Impact factor:   1.663


  6 in total

1.  Validation of plantar pressure measurements for a novel in-shoe plantar sensory replacement unit.

Authors:  Reed Ferber; Talia Webber; Breanne Everett; Marcel Groenland
Journal:  J Diabetes Sci Technol       Date:  2013-09-01

2.  Reliability of plantar pressure platforms.

Authors:  Jocelyn F Hafer; Mark W Lenhoff; Jinsup Song; Joanne M Jordan; Marian T Hannan; Howard J Hillstrom
Journal:  Gait Posture       Date:  2013-02-28       Impact factor: 2.840

3.  Reliability of Baropodometry on the Evaluation of Plantar Load Distribution: A Transversal Study.

Authors:  Daniel Baumfeld; Tiago Baumfeld; Romário Lopes da Rocha; Benjamim Macedo; Fernando Raduan; Roberto Zambelli; Thiago Alexandre Alves Silva; Caio Nery
Journal:  Biomed Res Int       Date:  2017-03-02       Impact factor: 3.411

4.  Repeatability of plantar pressure assessment during barefoot walking in people with stroke.

Authors:  A Rogers; S C Morrison; T Gorst; J Paton; J Freeman; J Marsden; M C Cramp
Journal:  J Foot Ankle Res       Date:  2020-06-29       Impact factor: 2.303

5.  Reliability and Repeatability of ACL Quick Check®: A Methodology for on Field Lower Limb Joint Kinematics and Kinetics Assessment in Sport Applications.

Authors:  Annamaria Guiotto; Alfredo Ciniglio; Fabiola Spolaor; Davide Pavan; Federica Cibin; Alex Scaldaferro; Zimi Sawacha
Journal:  Sensors (Basel)       Date:  2021-12-30       Impact factor: 3.576

6.  Variability of Postural Stability and Plantar Pressure Parameters in Healthy Subjects Evaluated by a Novel Pressure Plate.

Authors:  Allegra Fullin; Paolo Caravaggi; Pietro Picerno; Massimiliano Mosca; Silvio Caravelli; Antonio De Luca; Angela Lucariello; Paolo De Blasiis
Journal:  Int J Environ Res Public Health       Date:  2022-03-02       Impact factor: 3.390

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.