Literature DB >> 20566101

In vivo thrombogenicity of embolic protection systems for angioplasty and stenting.

J Raymond1, F Guilbert, A Metcalfe, I Salazkin, G Gevry, P Leblanc, A Weill, D Roy.   

Abstract

SUMMARY: Despite the increasing use of embolic protection systems (EPS) for carotid stenting, their intrinsic in vivo thrombogenicity remains unknown. We studied three different types of EPS (n = 24) deployed in the carotid arteries of pigs in which pools of platelets and fibrinogen were labelled with (111)In and (125)I. The amount of clot deposition seen on photography was also scored using a qualitative scale. EPS made of fabric nets under normal flow conditions were 5-6 and 15-16 times more thrombogenic (for both platelet (P=.04) and fibrin (P=.007)) than Nitinol mesh nets. Clot deposition on Nitinol mesh nets was more abundant under flow arrest than under normal flow conditions (P=.018). EPS differ in intrinsic thrombogenicity, a characteristic of the material that could be investigated in pre-clinical studies designed to optimize devices.

Entities:  

Year:  2008        PMID: 20566101      PMCID: PMC3329238          DOI: 10.1177/159101990701300403

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  5 in total

1.  Labelling of platelets with indium-111 oxine and technetium-99m hexamethylpropylene amine oxime: suggested methods. International Society of Radiolabelled Blood Elements (ISORBE).

Authors:  M Rodrigues; H Sinzinger; M Thakur; W Becker; M Dewanjee; M Ezekowitz; Y Isaka; J Martin-Comín; M Peters; M Roca; J Stratton
Journal:  Eur J Nucl Med       Date:  1999-12

Review 2.  Blood flow and antithrombotic drug effects.

Authors:  S R Hanson; K S Sakariassen
Journal:  Am Heart J       Date:  1998-05       Impact factor: 4.749

Review 3.  In vivo models of arterial thrombosis and thrombolysis.

Authors:  L R Bush; R J Shebuski
Journal:  FASEB J       Date:  1990-10       Impact factor: 5.191

Review 4.  Methods of assessment of thrombosis in vivo.

Authors:  M K Dewanjee
Journal:  Ann N Y Acad Sci       Date:  1987       Impact factor: 5.691

5.  Angioplasty and stenting of the cervical carotid bifurcation under filter protection: a prospective study in a series of 53 patients.

Authors:  G Bonaldi; L Aiazzi; F Baruzzi; F Biroli; A Facchinetti; P Fachinetti; A Lunghi; F Terraneo
Journal:  J Neuroradiol       Date:  2005-03       Impact factor: 3.447

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.