Balloon atrial septostomy guided by echocardiography in a neonatal intensive care unit.

Lilian M Lopes1, Christiane Kawano, Salvador André Bavaresco Cristóvão, Célia Toshie Nagamatsu, Luciana da Fonseca, Beatriz Helena Sanchez Furlanetto, Gláucio Furlanetto, José Pedro da Silva, José Armando Mangione.   

Abstract

BACKGROUND: The bedside two-dimensional echocardiography (2-D ECHO) has been successfully used to guide the balloon atrial septostomy, speeding up the procedure and preventing the risks of transportation to the hemodynamics laboratory.
OBJECTIVE: To assess the results of the bedside balloon atrial septostomy in cyanotic neonates.
METHODS: Between January/1997 and July/2008, 102 atrioseptostomies by balloon catheter guided by echocardiography were carried out and saturation levels, defect diameter, oxygen saturation, clinical-laboratory response and complications related to the procedure were evaluated.
RESULTS: Of 102 cases of bedside Rashkind septostomy, 98 met the inclusion criteria, with 90 neonates in Group A (Rashkind procedure in the preoperative phase) and 8 in Group B (procedure at the postoperative phase). There was a predominance of the male sex (75%), mean age was 8.3 ± 9.3 days and the mean weight was 3,100 ± 1,100 g; the transposition of the great arteries was the most frequent congenital heart disease (n = 74). When comparing the levels of saturation pre and post-procedure (65.9 ± 19.5% and 86 ± 9.7%) and the diameter of the interatrial septal defect pre and post-procedure (2.3 ± 1.0 mm and 5.5 ± 1.3 mm) there was a statistically significant difference (p < 0.001). When comparing the levels of saturation and the diameter of the interatrial septal defect between the group of survivors vs non-survivor, there was no statistically significant difference (p > 0.05).
CONCLUSION: The balloon atrial septostomy guided by the echocardiography reduces the risks by allowing the effective palliative procedure to be carried out promptly in cyanotic neonates, in addition to presenting lower hospital costs.

Entities:  

Mesh:

Year:  2010        PMID: 20563515     DOI: 10.1590/s0066-782x2010005000076

Source DB:  PubMed          Journal:  Arq Bras Cardiol        ISSN: 0066-782X            Impact factor:   2.000


  1 in total

1.  Echocardiography guided bed side balloon atrial septostomy in dextro transposed great arteries (dTGA) with intact ventricular septum (IVS): A resource limited country experience.

Authors:  Naresh Kumar; Abdul Sattar Shaikh; Veena Kumari; Najma Patel
Journal:  Pak J Med Sci       Date:  2018 Nov-Dec       Impact factor: 1.088