Literature DB >> 20560652

Scaling trace organic contaminant adsorption capacity by granular activated carbon.

Christopher J Corwin1, R Scott Summers.   

Abstract

The role of particle size on the reduction of granular activated carbon (GAC) adsorption capacity for trace organic contaminants by dissolved organic matter (DOM) is examined and applied to performance scale-up. The adsorption capacity reduction, termed fouling, must be scalable in order to use bench scale tests, such as the rapid small-scale column test (RSSCT) to predict full-scale breakthrough. Equilibrium adsorption capacity tests with GAC preloaded with DOM and RSSCT breakthrough curves at three different GAC particle sizes indicate that GAC adsorption capacity is dependent on GAC particle size when DOM is present. Thus, the RSSCT cannot be expected to match full-scale results regardless of which RSSCT design approach is used (constant or proportional diffusivity), unless a scaling factor is applied to the results. Proportional diffusivity RSSCT breakthrough curves demonstrate that surface concentration of DOM is not a good measure of fouling. It is hypothesized that pore blockage is the mechanism responsible for the dependence on particle size. As GAC particle size increases, the microporous surface area behind a constricted pore also increases. The result is lower adsorption capacity per mass of adsorbent in the larger GAC particles. A scaling methodology for equilibrium and breakthrough data is presented that accounts for the dependence of NOM preloading effects on GAC particle diameter.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20560652     DOI: 10.1021/es9037462

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  3 in total

1.  Emerging contaminants removal by granular activated carbon obtained from residual Macauba biomass.

Authors:  Flávia C C Moura; Regiane D F Rios; Breno R L Galvão
Journal:  Environ Sci Pollut Res Int       Date:  2018-07-10       Impact factor: 4.223

2.  Validating the use of lyophilized natural organic matter as background material in GAC rapid small-scale column tests.

Authors:  Gulizhaer Abulikemu; Thomas F Speth; Jeffrey A Vogt; Maria Meyer; Ying Hong; Jonathan G Pressman
Journal:  J Water Process Eng       Date:  2022-06

3.  Granular Activated Carbon Adsorption of Carcinogenic Volatile Organic Compounds at Low Influent Concentrations.

Authors:  David M Kempisty; R Scott Summers; Gulizhaer Abulikemu; Niranjan V Deshpande; Jacob A Rebholz; Kelsey Roberts; Jonathan G Pressman
Journal:  J Am Water Works Assoc       Date:  2020-03-08