Literature DB >> 20558982

Calf bioimpedance ratio improves dry weight assessment and blood pressure control in hemodialysis patients.

Yi-Lun Zhou1, Jing Liu, Fang Sun, Li-Jie Ma, Bin Han, Yang Shen, Tai-Gen Cui.   

Abstract

BACKGROUND: Chronic fluid overload due to overestimation of dry weight (DW) is the major factor in the development of hypertension in hemodialysis (HD) patients. The present study was undertaken to investigate whether bioimpedance ratio in the calf (Calf-BR = impedance at 200 kHz/impedance at 5 kHz) could be a useful hydration marker for estimation of DW and facilitate better control of blood pressure (BP) in HD patients.
METHODS: Target range of Calf-BR was derived from 157 healthy Chinese subjects. Post-dialysis Calf-BR was measured in 117 stable, non-edematous HD patients. Those with Calf-BR(s) above target level had their DW(s) gradually reduced under the guidance of Calf-BR.
RESULTS: The Calf-BR was normally distributed and increased with age, but was independent of BMI and gender in both healthy subjects and dialysis patients. HD patients with Calf-BR above age-stratified target range had significantly higher home BP, in spite of more antihypertensive treatments (p = 0.058). The patients who reached the target range of Calf-BR by decreasing DW, had their home BP significantly decreased, along with reduction in antihypertensive medications (p = 0.012).
CONCLUSION: Recognition and correction of chronic fluid overload based on age-stratified Calf-BR is helpful in hypertension control in Chinese HD patients. 2010 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2010        PMID: 20558982     DOI: 10.1159/000315135

Source DB:  PubMed          Journal:  Am J Nephrol        ISSN: 0250-8095            Impact factor:   3.754


  4 in total

Review 1.  Setting the dry weight and its cardiovascular implications.

Authors:  Arjun D Sinha; Rajiv Agarwal
Journal:  Semin Dial       Date:  2017-06-30       Impact factor: 3.455

2.  Impedance ratio: a novel marker and a powerful predictor of mortality in hemodialysis patients.

Authors:  C Demirci; G Aşcı; M S Demirci; M Özkahya; H Töz; S Duman; S Sipahi; S Erten; M Tanrısev; E Ok
Journal:  Int Urol Nephrol       Date:  2016-04-19       Impact factor: 2.370

3.  The effect of "xanthan gum-based fluid thickener" on hydration, swallowing functions and nutritional status in total maxillectomy patients.

Authors:  Baha Sezgin; Duygu Durusoy; Meltem Sezis Demirci; Kerem Ozturk; Isa Kaya; Sibel Eyigor; Sercan Gode
Journal:  Eur Arch Otorhinolaryngol       Date:  2018-10-22       Impact factor: 2.503

4.  Volume control by using the body composition monitor in a puerperal patient on hemodialysis.

Authors:  Wookyung Chung; Shung Han Choi; Jiyoon Sung; Eul Sik Jung; Dong Su Shin; Ji Yong Jung; Jae Hyun Chang; Hyun Hee Lee; Seung-Ho Lee; Sejoong Kim
Journal:  Electrolyte Blood Press       Date:  2011-12-31
  4 in total