Literature DB >> 20558097

The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models.

Purvi S D Patel1, Duncan E T Shepherd, David W L Hukins.   

Abstract

Screw fixation can be extremely difficult to achieve in osteoporotic (OP) bone because of its low strength. This study determined how pullout strength is affected by placing different bone screws at varying angles in normal and OP bone models. Pullout tests of screws placed axially, and at angles to the pullout axis (ranging from 10° to 40°), were performed in 0.09 g cm(-3), 0.16 g cm(-3) and 0.32 g cm(-3) polyurethane (PU) foam. Two different titanium alloy bone screws were used to test for any effect of thread type (i.e. cancellous or cortical) on the screw pullout strength. The cancellous screw required a significantly higher pullout force than the cortical screw (p<0.05). For both screws, pullout strength significantly increased with increasing PU foam density (p<0.05). For screws placed axially, and sometimes at 10°, the observed mechanism of failure was stripping of the internal screw threads generated within the PU foam by screw insertion. For screws inserted at 10°, 20°, 30° and 40°, the resistance to pullout force was observed to be by compression of the PU foam material above the angled screw; clinically, this suggests that compressed OP bone is stronger than unloaded OP bone.
Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20558097     DOI: 10.1016/j.medengphy.2010.05.005

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  16 in total

1.  Pullout Strength After Multiple Reinsertions in Radial Bone Fixation.

Authors:  Alfonso Mejia; Giovanni Solitro; Elena Gonzalez; Amit Parekh; Mark Gonzalez; Farid Amirouche
Journal:  Hand (N Y)       Date:  2018-09-06

2.  The fates of pedicle screws and functional outcomes in a geriatric population following polymethylmethacrylate augmentation fixation for the osteoporotic thoracolumbar and lumbar burst fractures with mean ninety five month follow-up.

Authors:  Hsi-Hsien Lin; Ming-Chau Chang; Shih-Tien Wang; Chien-Lin Liu; Po-Hsin Chou
Journal:  Int Orthop       Date:  2018-02-11       Impact factor: 3.075

3.  Effect of screw position on load transfer in lumbar pedicle screws: a non-idealized finite element analysis.

Authors:  Anna G U S Newcomb; Seungwon Baek; Brian P Kelly; Neil R Crawford
Journal:  Comput Methods Biomech Biomed Engin       Date:  2016-07-25       Impact factor: 1.763

4.  Kirschner wire prepared pilot holes improve screw pullout strength in synthetic osteoporotic-type bone.

Authors:  Hrayr G Basmajian; Joseph N Liu; Travis Scudday; Seth T Campbell; Nirav H Amin
Journal:  J Clin Orthop Trauma       Date:  2019-08-22

5.  Feasibility of using mixtures of silicone elastomers and silicone oils to model the mechanical behaviour of biological tissues.

Authors:  S Mohammad Hassan Ahmadzadeh; David W L Hukins
Journal:  Proc Inst Mech Eng H       Date:  2014-06-20       Impact factor: 1.617

6.  Pullout of a lumbar plate with varying screw lengths.

Authors:  Daniel Kyle Palmer; David Rios; Wyzscx Merfil Patacxil; Paul A Williams; Wayne K Cheng; Serkan İnceoğlu
Journal:  Int J Spine Surg       Date:  2012-12-01

7.  Balancing rigidity and safety of pedicle screw fixation via a novel expansion mechanism in a severely osteoporotic model.

Authors:  Thomas M Shea; James J Doulgeris; Sabrina A Gonzalez-Blohm; William E Lee; Kamran Aghayev; Frank D Vrionis
Journal:  Biomed Res Int       Date:  2015-02-01       Impact factor: 3.411

8.  Trabecular deformations during screw pull-out: a micro-CT study of lapine bone.

Authors:  Thomas Joffre; Per Isaksson; Philip Procter; Cecilia Persson
Journal:  Biomech Model Mechanobiol       Date:  2017-03-06

Review 9.  Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: current status.

Authors:  Thomas M Shea; Jake Laun; Sabrina A Gonzalez-Blohm; James J Doulgeris; William E Lee; Kamran Aghayev; Frank D Vrionis
Journal:  Biomed Res Int       Date:  2014-03-03       Impact factor: 3.411

10.  Comparative Analysis of Effect of Density, Insertion Angle and Reinsertion on Pull-Out Strength of Single and Two Pedicle Screw Constructs Using Synthetic Bone Model.

Authors:  Venkatesh Krishnan; Vicky Varghese; Gurunathan Saravana Kumar
Journal:  Asian Spine J       Date:  2016-06-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.