Neutralization efficacy of Dey-Engley medium in testing of contact lens disinfecting solutions.

S V Sutton1, T Wrzosek, D W Proud.   

Abstract

A quantitative assay for the demonstration of neutralizer efficacy was developed to monitor contact lens disinfecting solutions. Adequate neutralization of disinfecting agents is essential to the accurate determination of disinfecting activity with time. This method employed the recovery of small numbers of micro-organisms from neutralizing medium containing a disinfectant. A statistical estimation of significance between treatments demonstrated that Dey-Engley medium (DE; Difco) was generally effective when tested as an agar growth medium with several bacterial test organisms. DE medium from another vendor was less effective, underscoring the need for laboratory quality control and monitoring. DE agar (Difco) adequately neutralized all solutions tested at a 1:20 dilution. The solutions included those containing Dymed (polyaminopropyl biguanide, 0.00005%), chlorhexidine (0.005%), Polyquad (0.001%), chlorhexidine (0.005%) and thimerosal (BP, 0.001%), thimerosal (BP, 0.002%) and Tris(2-hydroxyethyl) tallow ammonium chloride (0.013%), and a solution preserved with 115 ppm benzalkonium chloride (BAK). A modification of this medium was developed which retained virtually all of the neutralizing efficacy for the solutions tested while allowing the use of automated testing procedures.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2055795     DOI: 10.1111/j.1365-2672.1991.tb02948.x

Source DB:  PubMed          Journal:  J Appl Bacteriol        ISSN: 0021-8847


  4 in total

1.  D-value determinations are an inappropriate measure of disinfecting activity of common contact lens disinfecting solutions.

Authors:  S V Sutton; R J Franco; D A Porter; M F Mowrey-McKee; S C Busschaert; J F Hamberger; D W Proud
Journal:  Appl Environ Microbiol       Date:  1991-07       Impact factor: 4.792

2.  A quantitative method to evaluate neutralizer toxicity against Acanthamoeba castellanii.

Authors:  S L Buck; R A Rosenthal
Journal:  Appl Environ Microbiol       Date:  1996-09       Impact factor: 4.792

3.  Sterile Reverse Osmosis Water Combined with Friction Are Optimal for Channel and Lever Cavity Sample Collection of Flexible Duodenoscopes.

Authors:  Michelle J Alfa; Harminder Singh; Zoann Nugent; Donald Duerksen; Gale Schultz; Carol Reidy; Patricia DeGagne; Nancy Olson
Journal:  Front Med (Lausanne)       Date:  2017-11-07

4.  Comparative lethality kinetic curves and predictive models of F-value for Listeria monocytogenes using different sanitizers.

Authors:  Cezar A Beltrame; Gabriela B Kubiak; Ieda Rottava; Geciane Toniazzo; Rogério L Cansian; Lindomar A Lerin; Débora de Oliveira; Helen Treichel
Journal:  Food Sci Nutr       Date:  2013-01-08       Impact factor: 2.863

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.