Literature DB >> 20556604

Ultrafast assessment of left ventricular dyssynchrony from nuclear myocardial perfusion imaging on a new high-speed gamma camera.

Aju P Pazhenkottil1, Ronny R Buechel, Bernhard A Herzog, Rene N Nkoulou, Ines Valenta, Ursula Fehlmann, Jelena-Rima Ghadri, Mathias Wolfrum, Lars Husmann, Philipp A Kaufmann.   

Abstract

PURPOSE: To validate the ultrafast assessment of left ventricular (LV) dyssynchrony by phase analysis using high-speed nuclear myocardial perfusion imaging (MPI) on a new gamma camera with cadmium-zinc-telluride (CZT) solid-state detector technology.
METHODS: In 46 patients rest MPI with 960 MBq (99m)Tc-tetrofosmin was acquired on a dual-head detector SPECT camera (Ventri, GE Healthcare) and an ultrafast CZT camera (Discovery NM 530c, GE Healthcare) with acquisition times of 15 and 5 min, respectively. LV dyssynchrony was assessed using the Emory Cardiac Toolbox with established values for histogram bandwidth (male <62.4°; female <49.7°) and standard deviations (male <24.4°; female <22.1°) as the gold standard. Evaluating CZT scan times of 0.5, 1, 2, 3 and 5 min (list mode) in 16 patients revealed the preferred scan time to be 5 min, which was then applied in all 46 patients. Intraclass correlation and the level of agreement in dyssynchrony detection between the CZT and Ventri cameras were assessed.
RESULTS: In LV dyssynchrony the mean histogram bandwidths with the CZT camera (n = 8) and the Ventri camera (n = 9) were 123.3 ± 50.6° and 130.2 ± 43.2° (p not significant) and 42.4 ± 13.6° vs. 43.2 ± 12.7° (p not significant). Normal bandwidths and SD obtained with the CZT camera (35.9 ± 7.7°, 12.6 ± 3.5°) and the Ventri camera (34.8 ± 6.6°, 11.1 ± 2.1°, both p not significant) excluded dyssynchrony in 38 and 37 patients, respectively. Intraclass correlation and the level of agreement between the CZT camera with a 5-min scan time and the Ventri camera were 0.94 (p < 0.001, SEE 14.4) and 96% for histogram bandwidth and 0.96 (p < 0.001, SEE 3.9) and 98% for SD.
CONCLUSION: This ultrafast CZT camera allows accurate assessment of LV dyssynchrony with a scan time of only 5 min, facilitating repeat measurements which would potentially be helpful for parameter optimization for cardiac resynchronization therapy.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20556604     DOI: 10.1007/s00259-010-1507-0

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  25 in total

1.  Cardiac resynchronization in chronic heart failure.

Authors:  William T Abraham; Westby G Fisher; Andrew L Smith; David B Delurgio; Angel R Leon; Evan Loh; Dusan Z Kocovic; Milton Packer; Alfredo L Clavell; David L Hayes; Myrvin Ellestad; Robin J Trupp; Jackie Underwood; Faith Pickering; Cindy Truex; Peggy McAtee; John Messenger
Journal:  N Engl J Med       Date:  2002-06-13       Impact factor: 91.245

2.  Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology.

Authors:  Roberto M Lang; Michelle Bierig; Richard B Devereux; Frank A Flachskampf; Elyse Foster; Patricia A Pellikka; Michael H Picard; Mary J Roman; James Seward; Jack S Shanewise; Scott D Solomon; Kirk T Spencer; Martin St John Sutton; William J Stewart
Journal:  J Am Soc Echocardiogr       Date:  2005-12       Impact factor: 5.251

3.  Long-term effect of cardiac resynchronisation in patients reporting mild symptoms of heart failure: a report from the CARE-HF study.

Authors:  J G F Cleland; N Freemantle; J-C Daubert; W D Toff; F Leisch; L Tavazzi
Journal:  Heart       Date:  2007-11-05       Impact factor: 5.994

Review 4.  Myocardial perfusion and function: single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Olakunle O Akinboboye; Daniel S Berman; Elias H Botvinick; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; Regina S Druz; Edward P Ficaro; James R Galt; Ravi K Garg; Guido Germano; Gary V Heller; Milena J Henzlova; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Robert A Quaife; Terrence D Ruddy; Senthil N Sundaram; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2007 Nov-Dec       Impact factor: 5.952

5.  Can LV dyssynchrony as assessed with phase analysis on gated myocardial perfusion SPECT predict response to CRT?

Authors:  Maureen M Henneman; Ji Chen; Petra Dibbets-Schneider; Marcel P Stokkel; Gabe B Bleeker; Claudia Ypenburg; Ernst E van der Wall; Martin J Schalij; Ernest V Garcia; Jeroen J Bax
Journal:  J Nucl Med       Date:  2007-06-15       Impact factor: 10.057

6.  The effect of cardiac resynchronization on morbidity and mortality in heart failure.

Authors:  John G F Cleland; Jean-Claude Daubert; Erland Erdmann; Nick Freemantle; Daniel Gras; Lukas Kappenberger; Luigi Tavazzi
Journal:  N Engl J Med       Date:  2005-03-07       Impact factor: 91.245

7.  Systolic improvement and mechanical resynchronization does not require electrical synchrony in the dilated failing heart with left bundle-branch block.

Authors:  Christophe Leclercq; Owen Faris; Richard Tunin; Jennifer Johnson; Ritsuchi Kato; Frank Evans; Julio Spinelli; Henry Halperin; Elliot McVeigh; David A Kass
Journal:  Circulation       Date:  2002-10-01       Impact factor: 29.690

8.  Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: a simulation study based on canine and patient data.

Authors:  C D Cooke; E V Garcia; S J Cullom; T L Faber; R I Pettigrew
Journal:  J Nucl Med       Date:  1994-07       Impact factor: 10.057

9.  Novel speckle-tracking radial strain from routine black-and-white echocardiographic images to quantify dyssynchrony and predict response to cardiac resynchronization therapy.

Authors:  Matthew S Suffoletto; Kaoru Dohi; Maxime Cannesson; Samir Saba; John Gorcsan
Journal:  Circulation       Date:  2006-02-13       Impact factor: 29.690

10.  Phase analysis of gated myocardial perfusion single-photon emission computed tomography compared with tissue Doppler imaging for the assessment of left ventricular dyssynchrony.

Authors:  Maureen M Henneman; Ji Chen; Claudia Ypenburg; Petra Dibbets; Gabe B Bleeker; Eric Boersma; Marcel P Stokkel; Ernst E van der Wall; Ernest V Garcia; Jeroen J Bax
Journal:  J Am Coll Cardiol       Date:  2007-04-05       Impact factor: 24.094

View more
  22 in total

1.  Downstream resource utilization following hybrid cardiac imaging with an integrated cadmium-zinc-telluride/64-slice CT device.

Authors:  Michael Fiechter; Jelena R Ghadri; Mathias Wolfrum; Silke M Kuest; Aju P Pazhenkottil; Rene N Nkoulou; Bernhard A Herzog; Cathérine Gebhard; Tobias A Fuchs; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-12-06       Impact factor: 9.236

2.  Advances in SPECT camera software and hardware: currently available and new on the horizon.

Authors:  E Gordon DePuey
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

Review 3.  Nuclear Image-Guided Approaches for Cardiac Resynchronization Therapy (CRT).

Authors:  Weihua Zhou; Ernest V Garcia
Journal:  Curr Cardiol Rep       Date:  2016-01       Impact factor: 2.931

Review 4.  Recent advances in cardiac SPECT instrumentation and system design.

Authors:  Mark F Smith
Journal:  Curr Cardiol Rep       Date:  2013-08       Impact factor: 2.931

5.  Novel 99mTc(III)-azide complexes [99mTc(N3)(CDO)(CDOH)2B-R] (CDOH2=cyclohexanedione dioxime) as potential radiotracers for heart imaging.

Authors:  Min Liu; Yumin Zheng; Ugur Avcibasi; Shuang Liu
Journal:  Nucl Med Biol       Date:  2016-05-09       Impact factor: 2.408

Review 6.  Nonechocardiographic imaging in evaluation for cardiac resynchronization therapy.

Authors:  Wael AlJaroudi; Ji Chen; Wael A Jaber; Steven G Lloyd; Manuel D Cerqueira; Thomas Marwick
Journal:  Circ Cardiovasc Imaging       Date:  2011-05       Impact factor: 7.792

7.  Cardiac resynchronization therapy in chronic heart failure: Effect on right ventricular function.

Authors:  Dominik C Benz; Aju P Pazhenkottil
Journal:  J Nucl Cardiol       Date:  2017-06-28       Impact factor: 5.952

8.  Interactions between myocardial sympathetic denervation and left ventricular mechanical dyssynchrony: A CZT analysis.

Authors:  Alessia Gimelli; Riccardo Liga; Francesca Menichetti; Ezio Soldati; Maria Grazia Bongiorni; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2017-08-14       Impact factor: 5.952

Review 9.  SPECT myocardial perfusion imaging for the assessment of left ventricular mechanical dyssynchrony.

Authors:  Ji Chen; Ernest V Garcia; Jeroen J Bax; Ami E Iskandrian; Salvador Borges-Neto; Prem Soman
Journal:  J Nucl Cardiol       Date:  2011-08       Impact factor: 5.952

10.  Does perfusion pattern influence stress-induced changes in left ventricular mechanical dyssynchrony on thallium-201-gated SPECT myocardial perfusion imaging?

Authors:  Harmandeep Singh; Chetan D Patel; Punit Sharma; Nitish Naik; Sandeep Singh; Rajiv Narang
Journal:  J Nucl Cardiol       Date:  2014-08-22       Impact factor: 5.952

View more