Literature DB >> 20555864

Fluorescence spectroscopy of turbid media: Autofluorescence of the human aorta.

M Keijzer, R R Richards-Kortum, S L Jacques, M S Feld.   

Abstract

Fluorescence spectra of turbid media depend on the geometry of excitation and collection. The geometry dependence of 476-nm excited fluorescence of the human arterial wall was investigated both experimentally and with a Monte Carlo simulation. Optical properties and the fluorescence yield of each of the three arterial layers were determined. Attenuation of fluorescence by wavelength dependent scattering and reabsorption causes the fluorescence spectra observed at the tissue surface to change with distance from the excitation beam. The ratio of 600-nm fluorescence to 580-nm fluorescence increases significantly beyond the excitation beam. This ratio depends on the amount of oxyhemoglobin in the sample, illustrating how reabsorption can influence autofluorescence measurements. The effects of different excitation/collection geometries on fluorescence spectra are discussed in relation to the design of catheters to differentiate normal and pathologic tissues.

Entities:  

Year:  1989        PMID: 20555864     DOI: 10.1364/AO.28.004286

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  26 in total

Review 1.  Fluorescence spectroscopy of neoplastic and non-neoplastic tissues.

Authors:  N Ramanujam
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

2.  Three-dimensional, multiwavelength Monte Carlo simulations of dermally implantable luminescent sensors.

Authors:  Ruiqi Long; Mike McShane
Journal:  J Biomed Opt       Date:  2010 Mar-Apr       Impact factor: 3.170

3.  Monte Carlo investigation on quantifying the retinal pigment epithelium melanin concentration by photoacoustic ophthalmoscopy.

Authors:  Xiao Shu; Wenzhong Liu; Hao F Zhang
Journal:  J Biomed Opt       Date:  2015-10       Impact factor: 3.170

4.  Influence of illumination-collection geometry on fluorescence spectroscopy in multilayer tissue.

Authors:  T J Pfefer; L S Matchette; R Drezek
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

5.  Measurement of fibrous cap thickness in atherosclerotic plaques by spatiotemporal analysis of laser speckle images.

Authors:  Seemantini K Nadkarni; Alberto Bilenca; Brett E Bouma; Guillermo J Tearney
Journal:  J Biomed Opt       Date:  2006 Mar-Apr       Impact factor: 3.170

6.  In vitro fluorescence measurements and Monte Carlo simulation of laser irradiation propagation in porcine skin tissue.

Authors:  E Drakaki; M Makropoulou; A A Serafetinides
Journal:  Lasers Med Sci       Date:  2007-08-03       Impact factor: 3.161

7.  A multimodal spectroscopy system for real-time disease diagnosis.

Authors:  Obrad R Sćepanović; Zoya Volynskaya; Chae-Ryon Kong; Luis H Galindo; Ramachandra R Dasari; Michael S Feld
Journal:  Rev Sci Instrum       Date:  2009-04       Impact factor: 1.523

8.  Accuracy of retinal oximetry: a Monte Carlo investigation.

Authors:  Wenzhong Liu; Shuliang Jiao; Hao F Zhang
Journal:  J Biomed Opt       Date:  2013-06       Impact factor: 3.170

9.  Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction.

Authors:  Adam J Dixon; John A Hossack
Journal:  J Biomed Opt       Date:  2013-05       Impact factor: 3.170

10.  Using an oblique incident laser beam to measure the optical properties of stomach mucosa/submucosa tissue.

Authors:  Hua Jiang Wei; Da Xing; Bo Hua He; Huai Min Gu; Guo Yong Wu; Xue Mei Chen
Journal:  BMC Gastroenterol       Date:  2009-08-28       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.